Download Print this page

Specification - Sherwood RX-772 Service Manual

Stereo receiver
Hide thumbs Also See for RX-772:

Advertisement

Measuring methods are based on IHF and IEC standard 268-3
Measurements conditions, unless otherwise noted :
Output resistive load = (8) ohms / Both channel driven
Tone(Bass, Treble), Balance, EQ control : Center Position , Other SW's : OFF
Nominal input level : 5mV for MM, 0.5mV for MC, 220mV for general purpose inputs
Power figures should be kept minimum 10min. between 15 and 35 ¡ É
Terminator : 100ohm for MC, 1kohm for MM and general purpose inputs
Filter : IHF-A filter
Power supply : 230V / 50Hz(RDS), 220V / 60Hz(K)
FRONT AMP SECTION ( 2-CH STEREO RECEIVER )
¡ Ü
No.
DESCRIPTION
1
INPUT SENSITIVITY
@ 1kHz , 47kΩ(RDS)
(K)
2
CHANNEL BALANCE
3
RESIDUAL NOISE, IHF-A FILTER
AT INPUT SHORTED
4
TOTAL HARMONIC DISTORTION
5
CONTINUOUS AVERAGE POWER
at (0.08)% THD
6
S/N RATIO, IHF-A FILTER
7
CHANNEL SEPARATION
AT INPUT SHORTED
8
FUNCTION CROSSTALK
AT INPUT SHORTED
9
FREQUENCY RESPONSE (-3dB)
1kHz Ref

SPECIFICATION

R/O = Rated Output
INPUT
FREQ.
EXT
1kHz
MIC
1kHz
MIC
1kHz
EXT
1kHz
1kHz
EXT
1kHz
20Hz
EXT
1kHz
20kHz
20Hz
EXT
1kHz
20kHz
EXT
1kHz
1kHz
EXT
10kHz
AUX¡ æ CD
1 kHz
CD¡ æ AUX
1 kHz
EXT
REMARK
UNIT
mV
mV
mV
R/O TO -40dB
dB
VOL min.
VOL max.
mV
%
R/O TO -3dB
%
%
W
8ohms
W
W
R/O
dB
dB
R/O
dB
dB
R/O
dB
1W
Hz~kHz
NOMINAL L/R LIMIT L/R
200±30
200±50
-
-
3±0.5
3±1
±0.5
±2
¡ Â 0.2
¡ Â 0.5
¡ Â 1.5
¡ Â 2
¡ Â 0.02
¡ Â 0.08
¡ Â 0.02
¡ Â 0.08
¡ Â 0.05
¡ Â 0.1
103
100
103
100
103
100
¡ Ã 95
¡ Ã 92
¡ Ã 65
¡ Ã 55
¡ Ã 45
¡ Ã 40
75
70
75
70
10~100
15~90

Hide quick links:

Advertisement

loading