Operation Overview - GE GFDS350 Technical Service Manual

Ha dryer with mist
Hide thumbs Also See for GFDS350:
Table of Contents

Advertisement

Air is pulled into the cabinet from the rear and drawn up across the heat source located behind the drum.
This hot air is pulled through the drum rear, across the clothes load, through the lint trap, and down the
trap duct into the blower. From the blower, the air is pushed out of the exhaust system. Overall heater
temperature is regulated by means of two temperature sensors: an inlet sensor located near the heating
elements, and an outlet sensor located at the blower. An additional safety thermostat, located near the
heating elements, shuts off the heating elements if they overheat. Also, the outlet backup thermostat,
located near the blower, provides additional safety and cycles the heaters if temperature goes above the
outlet temperature range.
Gas
Combustion
Chamber
Safety thermostat
Dryer
Cabinet
Safety thermostat
The typical dryer cycle progresses as follows:
1. A cycle is selected and the start key is pressed.
2. The motor is activated.
3. The heater elements (burner for gas models) are activated. The elements (burner) cycle on and off to
achieve the desired temperature throughout the heating portion of the cycle.
4. If sensor drying is selected, the heater elements (burner for gas models) are activated. The elements
(burner) cycle on and off until the load has achieved the desired dryness level.
5. If timed drying is selected, the heater elements (burner for gas models) are activated and cycle on and off
for the selected time at the selected temperature.
6. If STEAM DEWRINKLE or STEAM REFRESH is selected, the water valve is activated during heater elements
cycle on time (burner on time for gas models). See Cycle Matrix Chart on page 15.
7. The heater elements (burner for gas models) discontinue operation after the dryness level or elapsed time
has been achieved.
8. The motor continues operating until the clothes temperature drops below specifi ed temperature (Cool
Down).
9. The display turns off.

Operation Overview

Dryer Air Flow System
Diffuser
Inlet temperature
sensor
Heater
Pan/Electric
Elements
Inlet temperature sensor
Drum
Lint trap
– 21 –
Outlet backup
Exhaust
Blower
Outlet temperature sensor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfds355Gfdn240Gfdn245

Table of Contents