Main Control Board Resistance Checks
(Use if unable to verify operation in Service Mode)
Gas Valve Coils
Checked from the blue 3-pin connector with red, pink and white wires.
Upper valve coil = red and pink wires
Lower valve coil = red and white wires
Resistance should be approximately 1900 ohms for coils
Electric Dryer Heaters
Checked between the white and black relays.
Unplug the yellow wire from the white relay and measure between the yellow wire
and the blue wire on the black relay. Resistance should be approximately 40
ohms since the heaters are in series during this test.
Inlet Thermistor
Checked from the blue 2-pin connector with yellow and blue wires.
Unplug the connector and measure between the yellow and blue wires.
The resistance should be approximately 256K ohms at room temperature.