Gira 0334 Series Operating Instructions Manual

Radio weather station

Advertisement

Quick Links

Operating instructions
Radio weather station
0334 ..

Advertisement

Table of Contents
loading

Summary of Contents for Gira 0334 Series

  • Page 1 Operating instructions Radio weather station 0334 ..
  • Page 2 Notes regarding the battery Batteries and button cells do not belong in the hands of children. Contact a doctor immediately if a button cell has been swallowed. Replace empty batteries with an identical type or a type with the same values. Remove used batteries immediately and dispose of them in an environmentally-friendly way.
  • Page 3: Table Of Contents

    Table of contents Commissioning and installation Commissioning the radio sensor ..........4 Commissioning the radio weather station .........6 Replacing batteries ..............8 Resetting the weather station and radio sensor ......8 Selecting the installation site ............9 Installing the radio weather station .........10 Removing the radio weather station ........11 Installing the radio sensor ............12 Operating the radio weather station with the power adapter ................13...
  • Page 4: Commissioning The Radio Sensor

    Commissioning the radio sensor Front T H E R M O H Y G R O R F C L O C K Time Reception of radio controlled clock signal S E N S O R Temperature/Humidity Channel number, battery level LED status display Rear (battery compartment open) Wall mounting...
  • Page 5 On the back of the radio sensor: 1. Loosen and remove screws on battery compartment. 2. Set a radio channel (slider switch, SEARCH °C/°F RESET 1 2 3 4 5 EU UK ch. 1 - 5). Different radio channels must be set if several radio sensors are used.
  • Page 6: Commissioning The Radio Weather Station

    Commissioning the radio weather station Back (without mounting plate) Plug contact for power adapter Power supply (9 V) via a 230 V power adapter Polarity of the power adapter Battery compartment 2 x CR2032, 3 V Reset °C/°F mb/hPA / inHG mb/hPa / inHg switch Unit of air pressure display in mb/hPa or inHg...
  • Page 7 On the back of the radio weather station: 1. Insert button cells (2 x CR 2032 3 V) or connect the optional power adapter (see Page 13). Note the polarity shown. 2. Select the temperature unit with the °C/°F button. 3.
  • Page 8: Replacing Batteries

    Replacing batteries Battery replacement indicator The weather station features two battery replacement indicators. The indicator in the weather forecast area indicates the battery level in the radio weather station. The battery indicator in the tempera- ture/humidity area indicates the level of the batteries in the selected radio sensor.
  • Page 9: Selecting The Installation Site

    Selecting the installation site Testing signal transmission Before final installation, ensure that the positioning of the radio sensor(s) and radio weather station enable proper signal transmission. Conditions for optimum operation: • For optimum readability, the radio weather station should be installed at eye level (approx.
  • Page 10: Installing The Radio Weather Station

    Installing the radio weather station The radio weather station can be installed with or without a cover frame. If installed on a flush-mounted box (when used with power adapter), the weather station must be installed with a cover frame. Cover frames Wall mounting attachment Mounting plate Box mounting attachment...
  • Page 11: Removing The Radio Weather Station

    Box mounting 1. Connect power adapter to 230 V (see Page 13). 2. Place mounting plate and cover frame on the flush-mounted box. 3. Secure mounting plate to the support ring of the flush-mounted box with two screws. 4. Connect plug terminal and attach to the contact of the radio weather station.
  • Page 12: Installing The Radio Sensor

    Installing the radio sensor Find a suitable location for the radio sensor: Direct sunlight, rain or snow can negatively effect measurement. The radio sensor can be stood up or hung. Placing 1. Fold out stand on the back of the radio sensor and secure it there.
  • Page 13: Operating The Radio Weather Station With The Power Adapter

    Operating the radio weather station with the power adapter Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician. With the optional power adapter, the radio weather station can be operated with 230 V. The radio weather station must be installed on a flush-mounted box (we recommend a deep box) for this.
  • Page 14: Operating The Radio Weather Station

    Operating the radio weather station Front Weather forecast Animated weather forecast Battery level Power supply type (battery/power adapter) Temperature/Humidity Actual value, min./max. value, trend and comfort display, battery level of the radio sensors Barometer Trend display, 24 hour memory Radio controlled clock Time, calendar Moon-phase indicator CHANNEL...
  • Page 15: Weather Forecast

    Weather forecast The weather station creates a weather forecast for the next 12 to 24 hours for the area within a radius of 30 - 50 km. This forecast is based on air pressure trend measurements. The forecasted weather is indicated via animated symbols toward the top.
  • Page 16: Temperature/Humidity

    Temperature/Humidity The radio weather station can show the following information for each assigned radio sensor: • Current, minimum and maximum measured values for temperature and relative humidity (in percent). • Comfort zone (WET, COM, DRY) and trend symbols (rising, falling, steady). Displaying temperature and humidity of the radio sensors The individual radio sensors can be selected manually to have them display, for example, the outside temperature:...
  • Page 17 Displaying minimum/maximum values The radio weather station saves the minimum and maximum temperature and humidity values. These values can be polled as follows: 1. Press Mode until ▼ is found in the temperature/humidity area. 2. Choose between the inside temperature and the desired radio sensor (channels 1 through 5) with Ch.
  • Page 18 Calibrating display of inside temperature Depending on the installation site of the radio weather station, the displayed inside temperature may deviate from the actual room temperature. The display of the inside temperature can be adjusted by +/- 10° in 1° increments: 1.
  • Page 19: Barometer

    Barometer The weather station indicates the current air pressure and charts air pressure fluc- tuations to create a weather forecast. Displaying air pressure history The weather station saves the measured air pressure from the last 24 hours. These values are polled as follows: 1.
  • Page 20: Radio Controlled Clock

    Radio controlled clock The radio sensor automatically sets the time and date using official time signals from Mainflingen, Germany (near Frank- furt am Main) or Rugby (Great Britain). The time signals are received by the radio sensor if it is located within approx. 1,500 km from the time signal transmitter and are forwarded to the radio weather station.
  • Page 21 Setting time, date and language 1. Press Mode until ▼ is found in the clock area. 2. Press and hold Mode until the time zone compensation flashes. 3. Set the time zone compensation (+/- 23 hours) with Set and confirm with Mode. 4.
  • Page 22: Display Symbols

    Display symbols Trend display The temperature, humidity and air pressure trends are displayed via the following symbols: rising steady falling Moon-phase indicator The weather station calculates the corresponding phase of the moon using the date: waning crescent waning gibbous new moon full moon waxing crescent waning gibbous...
  • Page 23 House symbols The house symbol in the temperature/humidity area provides infor- mation on the selected channel and the reception status: Weather station is searching for radio sensors. Radio sensor on channel 1 transmitting data. (The number of the radio sensor is displayed). Weather station displays the data of the inside temperature and inside humidity.
  • Page 24: Technical Data

    Technical data Weather station Dimensions (H x W x D): 126 x 55 x 19 mm Temperature Measurement range: -5 °C to 50 °C (23 °F to 122 °F) Measurement increments: 0.1 °C (0.2 °F) Unit: °C or °F Relative humidity Measurement range: 25% to 95% Measurement increments:...
  • Page 25 Notes on care Use a moistened, soft and clean cloth to clean the radio weather station. Avoid quick repeated wiping of the radio weather station display. This can temporarily discolour the display. This discolouration dis- appears automatically after a short time.
  • Page 26: Warranty

    Warranty We provide a warranty in accordance with the statutory requirements. Please send the device postage paid with an error description to our central customer service centre. Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12 42477 Radevormwald, Germany...
  • Page 28 Gira Giersiepen GmbH & Co. KG Electrical Installation Systems Postfach 1220 42461 Radevormwald Germany Phone: +49(0)2195 - 602 -0 Fax: +49 (0) 21 95- 602-339 www.gira.de info@gira.de...

Table of Contents