Follow the steps in the order given to complete the installation process in a minimal amount of time.
Please read this section in its entirety before you begin the installation procedure outlined in the
sections that follow.
Decide on a suitable location for the rack unit that will hold the HD-220 unit. It should be situated
in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and
electromagnetic fields are generated. you will also need it placed near a grounded power outlet.
Choosing a Setup Location
A. Leave enough clearance in front of the rack to enable you to open the front door completely (~25
inches [63.5cm]).
B. Leave enough clearance on top of the unit to enable intake fan to work properly (minimum of 3/8
inches [1cm], recommended clearance is 1.75" [4.44cm])
C. Leave approximately 30 inches [76.2cm] of clearance in the back of the rack to allow for
sufficient airflow and ease in servicing.
Rack Precautions
A. Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the
full weight of the rack resting on them.
B. In a single rack installation, stabilizers should be attached to the rack.
C. In multiple rack installations, the racks should be coupled together.
D. Always make sure the rack is stable before extending a component from the rack.
E. you should extend only one component at a time - extending two or more simultaneously may
cause the rack to become unstable.
F. Always keep the rack's front door closed when not servicing to maintain proper cooling.
Basic HD-220 Bracket Installation Procedure
The HD-220 comes with two rack mounting brackets, which are attached on each side at the front of
the chassis with 3 screws
Installing the HD-220 into the Rack
To mount the system into a rack, simply screw these brackets directly to the front of the rack (two
screws for each bracket).
Rack Mounting Considerations Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack
environment may be greater than the ambient temperature of the room. Therefore, consideration
should be given to installing the equipment in an environment compatible with the VidyoRoom's
maximum rated ambient temperature (35°C [95 °F])
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation
is not compromised.
Mechanical Loading
TM
Equipment should be mounted into a rack so that a hazardous condition does not arise due to
uneven mechanical loading.