Installation Instructions
A. Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) of 40° C.
B. Reduced Air Flow – Installation of the equipment in a rack or cabinet should be such that the
amount of airflow required for safe operation of the equipment is not compromised.
C. Mechanical Loading – Mounting of the equipment in the rack or cabinet should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
D. Circuit Overloading – Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of the circuits might have on over current protec-
tion and supply wiring. Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
E. Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit. (e.g., use of power strips).
F. Redundant Power Supplies – Where redundant power supplies are provided with the equip-
ment, each power supply shall be connected to a separate circuit to optimize the equipment
redundancy.
G. Servicing – Prior to servicing the equipment, disconnect all power supplies.
H. Power Supply Cord – The power supply cord is used as the main disconnect device. Ensure that
the socket outlet is located/installed near the equipment and is easily accessible.
I. Circuit Overloading – This product relies on the building's installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S.
(240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors).
Additional Warnings
Caution: There is danger of explosion if battery is replaced with incorrect type. Replace the battery
with the same type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.