DutchWest 2466 Installation And Operating Manual

Direct vent natural vent gas heater
Table of Contents

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch;
do not use any phone in your
building.
• Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER FLAM-
MABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
This appliance may be installed in
an after market permanently located
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Direct Vent / Natural
Vent Gas Heater
Models: 2465, 2466
Homeowner's Installation
and Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
1935
Dutchwest
gas stove
cover
5/03
C E RT I F I E D
30001935 3/08 Rev. 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2466 and is the answer not in the manual?

Questions and answers

Summary of Contents for DutchWest 2466

  • Page 1 Direct Vent / Natural WARNING! IF THE INFORMATION IN THIS Vent Gas Heater MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- Models: 2465, 2466 SION MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed by a qualified...
  • Page 2: Table Of Contents

    Dutchwest Direct Vent / Natural Vent Gas Heater Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: General Information

    The Dutchwest Direct Vent/Natural Vent Room Heater, Model WARNING: Operation of this heater when not connected Nos. 2465 and 2466, is a vented gas appliance listed to the to a properly installed and maintained venting system ANSI standard Z21.88-2005 and CSA-2.33-2005 for Vented can result in carbon monoxide (CO) poisoning and pos- Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances...
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Dutchwest Direct Vent / Natural Vent Gas Heater Installation Requirements Requirements for the Commonwealth of Inspection Massachusetts The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber.
  • Page 5: Instructions Stove Dimensions

    Dutchwest Direct Vent / Natural Vent Gas Heater Dutchwest Direct Vent / Natural Vent Dimensions Refer to Page 6 for Flue Collar Centerline Dimensions 6���" (172mm) Valve Inlet 24���" (622mm) 28���" (721mm) C L Valve 4���" Inlet (111mm) 12���" 23" (318mm) (584mm) 17"...
  • Page 6: Installation Requirements

    Dutchwest Direct Vent / Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in Direct Vent System Only the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude.
  • Page 7: Parallel & Corner Installation

    Dutchwest Direct Vent / Natural Vent Gas Heater Wall Centerline from Floor Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natural Vent Stove Clearances A: 4” (102 mm) ST128c B: 4” (102 mm) ST131c Pipe Centerlines C: 15¹⁄₂” (395 mm) D: 9”...
  • Page 8: Gas Specifications

    2465 Millivolt 28,000 20,000 zontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal 2466 Prop Millivolt 28,000 19,000 termination must also meet the criteria shown in Figures Weight: Fully assembled; 202 lbs.
  • Page 9: Vertical Termination - Direct Vent Only

    Dutchwest Direct Vent / Natural Vent Gas Heater Vertical Termination - Direct Vent ONLY A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli- ance flue collar. A 2¹⁄₄” restrictor plate (supplied) must be used where specified in all vertically terminated vent systems.
  • Page 10 Dutchwest Direct Vent / Natural Vent Gas Heater Venting Termination Clearances Your stove is approved to be vented either through the There must not be any obstruction such as bushes, side wall, or vertical through the roof. garden sheds, fences, decks or utility buildings within 24”...
  • Page 11: General Venting Information - Termination Location

    Dutchwest Direct Vent / Natural Vent Gas Heater General Venting Information - Termination Location INSIDE CORNER DETAIL ����� ������ Fixed Operable Closed CFM145a AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12”...
  • Page 12: Termination Clearances

    Dutchwest Direct Vent / Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall...
  • Page 13: Venting Requirements And Options - Direct Vent Only

    Dutchwest Direct Vent / Natural Vent Gas Heater (1) Finishing plate (CG) Venting Requirements and Options - (1) Finishing collar (CG) Direct Vent ONLY (4) Polished Brass flue pipe rings Through the Wall Vent Kit 7TFSDVSK Approved Vent System Components (1) 90-Degree Elbow (CG) The Dutchwest Heater must be vented to the outdoors (1) 24”...
  • Page 14: Install The Optional Fan

    Dutchwest Direct Vent / Natural Vent Gas Heater • Remove retaining nut from shaft of rheostat. (if Install the Optional Fan preinstalled) If you are installing the optional convection Fan Kit • Insert the rheostat through the hole in the back #2767 (FK26), continue here.
  • Page 15: Venting System Assembly - Direct Vent

    Dutchwest Direct Vent / Natural Vent Gas Heater 5. Install the Outer Adapter Pipe. Apply a 1/4” bead Venting System Assembly - Direct Vent of cement around the inside wall of the pipe, about General Information 1” from the end. Insert the pipe over the stove flue collar, keeping the vertical seam oriented to the back The Dutchwest is approved for installation only with the of the stove.
  • Page 16: Install Vent Adapter Pipe (Simpson Dura-Vent Components)

    Dutchwest Direct Vent / Natural Vent Gas Heater Side Wall Termination Assembly Install the Vent Adapter Pipe 1. Locate the vent opening on the wall. Refer to Fig- (Simpson Dura-Vent Components) ure 5, Page 7, to determine the opening centerline. 1.
  • Page 17 Dutchwest Direct Vent / Natural Vent Gas Heater For DuraVent pipe only: Install vent pipe by align- ing the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before at- taching the horizontal run to the elbow.
  • Page 18: Vent Termination Below Grade

    Dutchwest Direct Vent / Natural Vent Gas Heater Vent Termination Below Grade Recessed Wall Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” Firestop (305mm) above grade level. The snorkel kit will allow Finishing installation depth of down to 7”...
  • Page 19: Venting System Assembly - Natural Vent

    Dutchwest Direct Vent / Natural Vent Gas Heater 8. Install appropriate pipe sections until the vent run Venting System Assembly - Natural Vent reaches above the flashing. The enlarged ends of General Information the vent sections always face downward. The Dutchwest Heater is shipped from the factory as 9.
  • Page 20: Install The Log Set

    Dutchwest Direct Vent / Natural Vent Gas Heater Attach the first section of venting to the draft hood. De- Left Log Right Log pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
  • Page 21: Burner Information

    Dutchwest Direct Vent / Natural Vent Gas Heater In the U.S.; Gas connection should be made in ac- Air Shutter Adjustment Instructions cordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have To adjust the air shutter, the following procedures additional local codes, be sure to consult your local should be followed: authority.
  • Page 22: Complete The Assembly

    Dutchwest Direct Vent / Natural Vent Gas Heater 8. The air shutter is located on the bottom of the burner Should color need further adjustment, repeat steps 1 to the left. (Fig. 37) Unfasten the two nuts holding - 12 for air shutter adjustment. the shutter in place.
  • Page 23: Thermostat Connection (Optional)

    Dutchwest Direct Vent / Natural Vent Gas Heater Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
  • Page 24: Operation

    Dutchwest Direct Vent / Natural Vent Gas Heater Operation Flame & Temperature Adjustment Your First Fire For stoves equipped with HI/LO valves, flame adjust- Read these instructions carefully and familiarize your- ment is accomplished by rotating the HI/LO adjustment self with the burner controls. Locate the pilot assembly, knob located near the center of the gas control valve.
  • Page 25: Lighting And Operating Instructions

    Dutchwest Direct Vent / Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 26: Troubleshooting - Honeywell #8420 Gas Control System

    Dutchwest Direct Vent / Natural Vent Gas Heater Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 27: Fuel Conversion Instructions

    Dutchwest Direct Vent / Natural Vent Gas Heater Fuel Conversion Instructions WARNING! This conversion kit shall be installed Remove Screws Rear Log Bracket by a qualified service agency in accordance with the manufacturer’s instructions and all applicable Pilot codes and requirements of the authority having jurisdiction.
  • Page 28 Dutchwest Direct Vent / Natural Vent Gas Heater Pilot Hood Pilot Bracket CO105a Fig. 53 Remove pilot hood. Allen Wrench Index Tab CO105a gas conversion FC107 Pilot Fig. 51 Remove mounting screws, pressure regulator tower 1/28/00 djt and spring and diaphragm assembly. Snap Ring CO106a FC107...
  • Page 29 Dutchwest Direct Vent / Natural Vent Gas Heater 21. Replace burner. Slide the burner in at an angle Left Burner Leg with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg Injector Shoulder remains at a 90°...
  • Page 30: Maintenance

    Dutchwest Direct Vent / Natural Vent Gas Heater Maintenance Your Dutchwest Gas Heater will provide years of ser- CAUTION vice with minimal upkeep. The following procedures will help ensure that your stove continues to function TURN THE PILOT OFF BEFORE PAINTING. ALLOW THE HEATER TO COOL COMPLETELY BEFORE properly.
  • Page 31: Gasket Replacement

    Dutchwest Direct Vent / Natural Vent Gas Heater Inspect the Vent System Annually Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspect- ing the system. Both the inner exhaust pipe and the out- er combustion supply pipe must be checked to confirm that they are unblocked and in good condition.
  • Page 32: Wiring Diagram

    Dutchwest Direct Vent / Natural Vent Gas Heater Wiring Diagrams POWER On/Off Switch Wiring CORD Chassis TP/TH Ground Millivolt Gas Valve Black ST124b Thermostat Optional Thermostat FAN JUNCTION BOX (Optional) Thermostat (Optional) Wiring Strain Relief St124b ON / OFF on/off/switch TP/TH Rheostat wiring...
  • Page 33: Replacement Parts

    CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 1935 Dutchwest Direct Vent / Natural Vent Gas Heater Dutchwest parts 5/16/03 djt Models 2465, 2466 Ref. Description Dutchwest Gas Log Assembly - SDV30 20003458 Rear Log...
  • Page 34 *Use common super glue or silicone to attach magnets. *When converting to SIT valve, must order RP275 **When converting to SIT valve, must order RP269 Fuel Conversion Kits Conversion Kit, NG to LP - 2465 Kit #000-5022 Conversion Kit, LP to NG - 2466 Kit #000-5021 30001935...
  • Page 35: Optional Accessories

    Dutchwest Direct Vent / Natural Vent Gas Heater Optional Accessories Fan Kits Remote Controls FK26 Fan The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 32 for The FK26 fan helps distribute heated air from within wiring diagrams.
  • Page 36 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935...
  • Page 37 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935...
  • Page 38 Dutchwest Direct Vent / Natural Vent Gas Heater 30001935...
  • Page 39: Warranty

    Dutchwest Direct Vent / Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner. • Any part and/or component replaced under the provisions of this BASIC WARRANTY warranty is covered for six months or the remainder of the original CFM Corporation Company (hereinafter referred to collectively as the warranty, whichever is longest.
  • Page 40: Energuide

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

2465

Table of Contents