• Easy ‘How to use’ guides for storage heaters • Service and repairs • Where to buy our products • Literature downloads • Heating requirement calculator Visit ‐ www.dimplex.co.uk/support A division of GDC Group Ltd Registered No: 1313016 England VAT GB 287 1315 50004 Millbrook House Grange Drive Hedge End Southampton SO30 2DF EEE Producer Registration Number –...
Page 2
Westcott 4.3kW Multifuel Inset Stove For Standard 16” Fireplace Opening Please hand these instructions to the stove user when installation is complete. Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls.
Page 3
L (Dia) Table 1 - Dimensions Westcott Insert Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”) Westcott Inset WST4i Table 2 - Technical Specification Wood Solid Fuel Nominal heat output Efficiency 80.9...
non combustible wall Fireplace Opening min thick Y 400mm (16”) fireback and insulated infill CONSTRUCTIONAL HEARTH min 225mm NON COMBUSTIBLE 125mm THICK MINIMUM Z = At least 150mm or to a suitably heat resistant wall Typical installation Lintel or Gather Clay Flue pipe Fireback to BS1251...
- 1 - Wescott 4.3kW Multifuel Inset Stove (WST4i) IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Fire Cement/Glue: Some types of fire cement/glue are caustic Important Safety Advice and should not be allowed to come into contact with the skin. Use suitable protective gloves when handling.
- 2 - the contents including the fixing bar (Fig 4). needs further attention. Any remedial work to the chimney flue should be carried out by a suitably Qualified Engineer. Secure the fixing bar using the hinge pins and after feeding the tightening bar through the fixing bar, add the washers and A flue draught of minimum 12 Pascal to maximum 25 Pascal is wingnut onto the end (1 &...
- 3 - Air Controls Shutting Down Primary air is controlled via the sliding vents (Fig 2a) in the bottom To shut down the stove, close the primary air controls and then of the door; this provides a conventional air draught to the bed of the secondary air controls by moving both sliders to the left.
Stove Body The stove is finished with a heat resistant paint and this can be As a sign of our commitment to quality, all new Dimplex solid cleaned with a soft brush. Do not clean while the stove is hot, fuel stoves are guaranteed against casting faults and other wait until it has cooled down.
Westcott 4.3kW Inset (WST4i) WESTCOTT 4.3KW INSET STOVE (WST4i) - SPARE PARTS Item Description Part Number Item Description Part Number DOOR 3011013 LOG BAR 3011024 DOOR PINS (X2) 3011014 GRATE 3011025 DOOR GLASS 3011015 BACK PLATE 3011096 PRIMARY AIR SLIDE...