Installation And Operating Instructions - Dimplex DY73 Installation And Operating Instructions

Convector heaters

Advertisement

Dimplex Convector Heaters
Models : DY73, DY77 and DY78.
Dimensions
(millimetres)
Models
Specification
DY73
2.0kw Switch/Thermostat
DY77
2.0kw 2 Neon Switches/Thermostat/Turbo
DY78
3.0kw 2 Switches/Thermostat/Neon
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
IMPORTANT SAFETY ADVICE
WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
NEVER cover or obstruct in any way the heat outlet slots at the top
of the heater or the air inlet slots in the base of the heater.
The heater carries a warning 'DO NOT COVER' to alert the user to the
risk of fire that exists if the heater is accidentally covered.
If young children, the aged or infirm are likely to be left in the vicinity
of the heater, we advise that adequate precautions should be taken.-
We recommend that a guard be fitted to ensure contact with the
heater is avoided and objects cannot be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
For further information, please contact our guard supplier direct on
Tel. No. 01603 667957, or in case of difficulty or for further advice
contact the Customer Helpline.
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is fitted with
a rewirable plug incorporating a 13 amp fuse. In the event of replacing the
fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS 1362
must be used. If any other type of plug is used, a 15 amp fuse must be
fitted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug
should be removed. Before wiring the appropriate plug, please note that
the wires in this mains lead are coloured in accordance with the following
code :
GREEN AND YELLOW :
BLUE :
BROWN :
Connect the GREEN AND YELLOW wire to the terminal marked 'E' or by
the earth symbol
, or coloured GREEN or GREEN AND YELLOW.
Connect the BROWN wire to the terminal marked 'L' or coloured RED.
Connect the BLUE wire to the terminal marked 'N' or coloured BLACK.
EARTH
NEUTRAL
LIVE

Installation and Operating Instructions

230
697 - 3.0kw
577 - 2.0kw
MIN
432
Wall Mounting
Three identical wall mounting brackets are secured to the base of the
heater with a fixing screw. To wall mount appliance, first remove the
brackets as follows :
Lay the heater on its back. Following the sequence in Fig. 1 – identify
and remove the fixing screw securing the brackets located beside Mains
Cable as shown in (a), then pull out brackets and rotate them to
disengage them from the slot (b).
Withdraw the brackets from the slot (c).
(a)
Select a suitable position on a wall, near to a mains power socket,
making sure that there is at least 230 mm below the heater and at least
450 mm above the heater of unobstructed space. See also 'Positioning
the heater'.
Fix the two top retaining brackets to the wall, using suitable fixings, for
2kw models at 358 mm centres and the 3kw model at 478 mm centres –
see Fig 2.
Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.
INDCUK3BQR
230
156
MIN
Floor Mtd.
(b)
(c)
3 No. Wall
Mounting
Brackets
Issue 0
450
MIN
357
230
MIN
Wall Mtd.
Fig. 1
shelf /
ceiling
526 mm
min.
bracket
slot
520 mm
min.
floor
Fig. 2