Installation & Owner's Manual
MODELS
RLCA-RLHA 07-30
RLCB-RLHB 07-28
RACC-RAHC 07-28
EN 035M80147-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RLCA-RLHA 07-30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for York RLCA-RLHA 07-30

  • Page 1: Air Conditioner

    Installation & Owner’s Manual MINISPLIT MODELS RLCA-RLHA 07-30 HIGH WALL RLCB-RLHB 07-28 RACC-RAHC 07-28 AIR CONDITIONER The units comply with one or more of the following marks - see unit for details. EN 035M80147-000 J277-EN.indd revise by Arisa 16/02/06 J277-EN 1...
  • Page 2: Table Of Contents

    CONTENTS Safety Precautions ............3 Part Names ..............4 Manual Operation ............5 How the air conditioner works ........5 Optimal operation ............6 Preparation Before Installation ........6 Installation Procedure ..........8 Maintenance ............... 15 Operation tips ............16 Please read this installation Troubleshooting Guide ..........
  • Page 3: Safety Precautions

    REQUIRED TOOLS EXTENDED PARTS 1. Screw driver 9. Manifold gauge 1. Refrigerant Pipe 2. Hexagonal wrench 10. Gas leak detector Models 07-09 12-18 24-30 3. Torque wrench 11. Vacuum pump Liquid size 1/4 inch 1/4 inch 3/8 inch 4. Spanner 12.
  • Page 4: Part Names

    PART NAMES INDOOR UNIT ■ INDOOR & OUTDOOR UNIT Front panel Remote controller signal Air inlet receiver Air fi lter Remote controller Air outlet Manual control button Horizontal air fl ow grille Connecting pipe, drain hose Vertical air fl ow louver Air inlet (side and rear) Display panel Air outlet...
  • Page 5: Manual Operation

    MANUAL OPERATION Manual operation can be used temporarily in case you can not fi nd the remote controller or its batteries are exhausted. 1 Open and lift the front panel up to an angle at which it remains fi xed with a clicking sound. 2 Press the button until the AUTO indicator is lit, the unit will work in forced AUTO mode.
  • Page 6: Optimal Operation

    OPTIMAL OPERATION To achieve optimal performance, Please note the following: • Adjust the air fl ow direction correctly so that it is not directed on people. • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.
  • Page 7: Rlda-Rlja 07-09, Rldb-Rljb

    OUTDOOR UNIT PICTURES RLDA-RLJA 07-09, RLDB-RLJB 07-09, RLDB-RLJB 18 RADC-RAJC 07 RLDA-RLJA 24-30, RLDB-RLJB 24-28, RLDA-RLJA 12-18, RLDB-RLJB 12, RADC-RAJC 09-12 RADC-RAJC 18-28 301.5 Ø420 141.5 560.1 ENGLISH J277-EN.indd 7 J277-EN.indd 7 26.12.2005 15:15:18 Uhr 26.12.2005 15:15:18 Uhr...
  • Page 8: Installation Procedure

    PARTS INSTALLATION Number Name of part Q’ty Installation plate Clip anchor Self-tapping screw A ST3.9X25 Liquid side ø 6.35 ø 9.53 (<12000Btu/h model) Connecting Parts you pipe must ø 12.7 (21000Btu/h model > Cooling Gas side assembly capacity f 12000Btu/h model) purchase ø...
  • Page 9: Drain Hose

    MODEL 24-30 Above 150mm from the ceiling Hooked Part Hooked Part Hooked Part 1080 Above 120mm from Above 120mm from the wall Right the wall Right Pipe hole Pipe hole Indoor Unit Outline Right Left Right CAUTION Rear Bottom • Be careful when handling the sharp edge of the mount- ing plate.
  • Page 10: Indoor Unit Fixing

    ■ Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole. • Hang the top of the unit onto the upper ridge of them in mounting plate. • Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. •...
  • Page 11 To this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves.
  • Page 12: Electrical Connections

    ■ Wiring Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the model. CAUTIONS •...
  • Page 13: Wiring Connection

    ■ Wiring Connection Models : 07-18 Indoor Outdoor Terminal block of indoor unit Terminal block of outdoor unit 1 2(N) 3 4 1 2(N) 3 4 2(N) 2(N) 3 Cord clamp Wire-holding To outdoor unit To outdoor unit board Cooling & heating type Cooling only type Cooling &...
  • Page 14: Electrical Work

    ■ Electrical Work Model Power Source Switch and Fuse rating Wiring size 220-240V ~ 50Hz f 1.0 mm 7000-9000 Btu/h 220-230V ~ 60Hz 220-240V ~50Hz f 1.5 mm 12000 Btu/h 220-230V ~ 60Hz 220-240V ~50Hz 18000 Btu/h 220-230V ~ 60Hz f 2.5 mm 220-240V ~50Hz 24000-30000 Btu/h...
  • Page 15: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and disconnect the power Household supply before cleaning. Drain Cleaner ■ Cleaning the indoor unit and remote controller CAUTION • Use a dry cloth to wipe the indoor unit and remote controller. •...
  • Page 16: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection • The compressor can not restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 17: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not 1. Power failure. 1. Wait for power resume. 2. Fuse blown or circuit breaker open. 2. Replace the fuse or reset the run. 3. Voltage is too low. breaker.
  • Page 18: Technical Specifi Cation

    TECHNICAL SPECIFICATIONS Technical Specifi cations : Everest RLCA-RLHA “R22” - 50Hz RLEA-RLKA Indoor Unit RLEA07 RLKA07 RLEA09 RLKA09 RLEA12 RLKA12 RLEA18 RLKA18 RLEA24 RLKA24 RLEA28 RLKA28 Models RLDA-RLJA Outdoor Unit RLDA07 RLJA07 RLDA09 RLJA09 RLDA12 RLJA12 RLDA18 RLJA18 RLDA24 RLJA24 RLDA28 RLJA28 V/Ph/Hz 220-240/1/50 Power Supply...
  • Page 19: Technical Specifications

    TECHNICAL SPECIFICATIONS Technical Specifi cations : Everest RLCA-RLHA “R22” - 60Hz RLEA-RLKA Indoor Unit RLEA07 RLKA07 RLEA09 RLKA09 RLEA12 RLKA12 RLEA18 RLKA18 RLEA24 RLKA24 RLEA30 RLKA30 Models RLDA-RLJA Outdoor Unit RLDA07 RLJA07 RLDA09 RLJA09 RLDA12 RLJA12 RLDA18 RLJA18 RLDA24 RLJA24 RLDA30 RLJA30 V/Ph/Hz 220-230/1/60 Power Supply...
  • Page 20 TECHNICAL SPECIFICATIONS Technical Specifi cations : Everest RLCB-RLHB “R407C” - 50Hz RLEB-RLKB Indoor Unit RLEB07 RLKB07 RLEB09 RLKB09 RLEB12 RLKB12 RLEB18 RLKB18 RLEB24 RLKB24 RLEB28 RLKB28 Models RLDB-RLJB Outdoor Unit RLDB07 RLJB07 RLDB09 RLJB09 RLDB12 RLJB12 RLDB18 RLJB18 RLDB24 RLJB24 RLDB28 RLJB28 V/Ph/Hz 220-240/1/50 Power Supply...
  • Page 21: Radc-Rajc

    TECHNICAL SPECIFICATIONS Technical Specifi cations : Everest RACC-RAHC “R410A” -50Hz RAEC-RAKC Indoor Unit RAEC07 RAKC07 RAEC09 RAKC09 RAEC12 RAKC12 RAEC18 RAKC18 RAEC24 RAKC24 RAEC28 RAKC28 Models RADC-RAJC Outdoor Unit RADC07 RAJC07 RADC09 RAJC09 RADC12 RAJC12 RADC18 RAJC18 RADC24 RAJC24 RADC28 RAJC28 V/Ph/Hz 220-240/1/50 Power Supply...
  • Page 22: Declaration Of Conformity

    Authorized Representative: CM Choi Shipping Manager YORK International (Northern Asia) Ltd. 15/F., Tower II, World Trade Square, 123 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong Telephone: (852) 2331 9286 Fax: (852) 2331 9840 Technical Service Division: Telephone: (852) 2331 9286 Fax: (852) 2304 0068...