Chapter 6 Output Format - Omega DR130 SERIES User Manual

Communication interface
Table of Contents

Advertisement

5.6 Control and Execution Command
p2
File name (up to eight characters)
p3
First output channel number
p4
Last output channel number
p5
First output data number
p6
Last output data number
Comments • This command is effective only with an optional
floppy disk drive.
• Always specify data that are output with TS
command before sending MF command, and execute
[GET] or [ESCT].
• If p1 is set to 0 (file directory), the settings for p2 to
p6 will be invalid.
• If p1 is set to 3 (on/off information on the channel
on which the specified file
exists), the settings for p5 and p6 will be invalid.
• Parameters p5 and p6 are set in the range from 1 to
the last data number in a file.
• Channel numbers are recognized in the order of input
channel and channel for computation. If you set 005
for the first channel and A10 for the last channel,
the target computation will be done in input channel
005 to the last input channel as well as channels A01
to A10.
RF
Selects the output format of the report.
Mode
Operation mode
Setting
RFp1, p2, p3<terminator>
p1
0 Output hourly report data
1 Output daily report data
2 Output monthly report data
3 Output the status of the hourly/daily/
monthly data
p2
First channel for output (R01 to R30)
p3
Last channel for output (R01 to R30)
Comments • Before transmitting the RF command, be sure to
specify the data to output using the TS command
and execute "GET."
• If the daily report is to be output using extended
format, the extended information must be output
within 1 hour from the creation of the report. If the
monthly report is to be output using extended format,
the extended information must be output within 1
day from the creation of the report. After that, the
extended information can not be output.
• If there is no valid data within the specified report
channel range, "FFFFH" is output.
LF
Specifies the output channels for
setting data output, unit, and decimal
point data.
Mode
All modes
Setting
LFp1, p2<terminator>
p1
First output channel (001 to 030)
First output computed channel (A01 to A30)
p2
Last output channel (001 to 030)
Last output computedchannel (A01 to A30)
Comments • You must specify data to be output with the TS
command and execute "GET" or "ESC T" before
sending the LF command.
• If no input channel is recognized by the DR230/
DR240 among the specified channels, a syntax error
occurs.
• The optional computation channel number is A01
to A30.
CF
Specifies the system configuration
output format.
5-20
Mode
All modes
Setting
CFp1<terminator>
p1
0 Information on system-configured modules
1 Current status module information (real-time
information)
Comments • You must specify data to be output with the TS
command and execute "GET" or "ESC T" before
sending the CF command.
BO
Specifies the order of byte output
(in binary output).
Effective mode Operation mode
Setting
BOp1<terminator>
p1
0 Output from MSB (upper-digit byte)
1 Output from LSB (lower-digit byte)
IM
Specifies the mask of a status
byte.
Mode
Operation mode
Setting
IMp1<terminator>
p1
First numerical value of the items (or
combination of those values) shown below
0
All interrupts are OFF.
1
Interrupt occurs at the end of an A/D
conversion.
2
Interrupt occurs at the time of a syntax
error.
4
Interrupt occurs when internal timer is
being operated or the time for hourly,
daily and monthly reports arrives.
8
Interrupt generated after storing data on
media, or reading data from media.
16
Interrupt occurs at the time of a chart
end.
32
Interrupt generated when measurement
release is generated while computation
is in progress.
Comments • Masks the causes of interrupt in the status byte.
• When either of the phenomena effectively specified
with this command occurs, bit 7 (SRQ) of the status
byte is set to "1" and causes an interrupt to the
controller.
• For detailed instructions on the status byte, see Pages
1-2 and 2-2.
SM
Sets the auxiliary mask of the status
byte.
Mode
Operation mode
Setting
SMp1<terminator>
p1
A figure determined by the following
calculation:
p1 = a + b + c + d + e + f + g
a=1 Interrupt occurs when timer No. 1
=0
b=2 Interrupt occurs when timer No. 2
=0
c=4 Interrupt occurs when timer No. 3
=0
d=8 Interrupt occurs when timer No. 4
=0
e=16 Interrupt occurs when timer No. 5
=0
operates.
No interrupt occurs.
operates.
No interrupt occurs.
operates.
No interrupt occurs.
operates.
No interrupt occurs.
operates.
No interrupt occurs.

Advertisement