Dialer Programming ( ∗ 40 – ∗ 50)
FIELD
TITLE and DATA ENTRIES

PABX Access Code

*40
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)

Primary Phone No.

*41
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)

Secondary Phone No.

*42
Enter up to 20 digits.
0–9, # + 11 for ' ✱ ', # + 12 for '#', # + 13 for a
pause (2 seconds)
Part. 1 Primary Subs. Acct. No.
*43
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 1 Secondary Subs. Acct. No.
*44
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Primary Subs. Acct. No.
*45
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Secondary Subs. Acct. No.
*46
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Phone System Select
*47
If Central Station Receiver is not on WATS
line: 0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial; 3 = Tone Dial
Report Format
*48
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = ADEMCO Contact ID® 10-digit Format
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO Contact ID® 4-digit Format
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Split/Dual Reporting
*49
0 = standard/backup reporting only
(all reports only to primary unless
unsuccessful, then will attempt
secondary)
1 - 5 (see table to right)
Burglary Dialer Delay
*50
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
SESCOA/Radionics Select
*53
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
EXPLANATION
To clear entries from field, press ∗40∗. If fewer than 6 digits need to
be entered, exit by pressing [∗], which advances to the next field.
Call Waiting: If the subscriber's phone service has "call waiting"
(and is not using PABX), enter "*70" ("# + 11") plus "# + 13" (pause)
as the PABX entry to disable "call waiting" during control panel calls.
If the subscriber does not have "call waiting" and is not using PABX,
make no entry in this field.
If you enter fewer than 20 digits, exit by pressing [∗]. To clear entries
from field, press ∗41∗.
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the
primary number) is automatic only if there is a secondary phone
number (field ∗42).
If you enter fewer than 20 digits, exit by pressing [∗]. To clear entries
from field, press ∗42∗. See backup reporting note for field ∗41.
Don't fill unused spaces.
To clear entries from field, press ∗43∗.
To clear entries from field, press ∗44∗.
FA168CPS.
To clear entries from field, press ∗45∗.
FA168CPS.
To clear entries from field, press ∗46∗.
Select the type of telephone service.
Select report format for primary and secondary phone numbers.
(Primary/Secondary)
1 = alarms, restore, cancel
2 = all except open/close, test
3 = alarms, restore, cancel
4 = all except open/close, test
5 = all
Provides delay of "BURGLARY ALARM" report to the central
station, which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms
(silent burglary) or to 24-hour zone types 6, 7, and 8 (silent panic,
audible alarm, auxiliary alarm), which are always sent as soon as
they occur.
UL: must be "0"
SIA Installations: delay must be minimum of 30 seconds
Select SESCOA or Radionics format.
Select 0 for all other formats.
To Primary No.
To Secondary No.
others
open/close, test
all
all
all