Long Range Radio Connections - First Alert FA168CPS Installation And Setup Manual

Hide thumbs Also See for FA168CPS:
Table of Contents

Advertisement

Long Range Radio Connections

Connect the data in/data out terminals and voltage
input terminals of the Long Range Radio to the
control's keypad connection points.
Set the radio's address to "03" following the
instructions provided with the radio.
Audio Alarm Verification Connections
(AAV, "listen-in")
Refer to the connection diagrams below. One diagram
shows connections when a FA4285/FA4286 Phone
Module is used, the other shows connections when
the FA4285/FA4286 is not used.
Connections use one of the on-board triggers.
U L
UL installations using the AAV feature must use the
ADEMCO UVCM module (part of the ADEMCO UVS
system).
Suggested Module: ADEMCO UVS (shown) or Eagle 1250
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = OFF
2 = ON
3 = OFF
3 = OFF
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 15. Connection of AAV Unit When Not Using a FA4285/FA4286 Phone Module
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = OFF
2 = ON
3 = OFF
3 = OFF
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 16. Connection of AAV Unit When Using a FA4285 or FA4286 Phone Module
CONTROL
AUXILIARY
4
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
MODULE
FALLING VOICE TRIG
GND
+12VDC IN
CONTROL
AUXILIARY
4
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
RING
MODULE
TIP
FALLING VOICE TRIG
GND
+12VDC IN
Mounting and Wiring the Control
Notes
• Use compatible Long Range Radios (e.g.,
7720PLUS, 7820, 7835C, or 7845C).
Notes
• Set field *91 for AAV and program the
appropriate output (output 17 or 18) using *80
Menu mode (select zone type "60").
• For voice session monitoring, connect an EOLR
zone to UVCM module terminals 6 & 7, and
program the zone as zone type 81 (*56 Menu
mode).
E.g., Using output 18 for the trigger, program an
output function in *80 Menu mode as: ZT = 60,
P = 0, Action = 1, Device = 18
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
5
21
22
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
5
21
22
EOL
RING
TIP
OPTIONAL
MONITORING
ZONE
CONNECTION
(USE ZONE
TYPE 81)
FA4285/FA4286
4
3
2
1
EARTH
GROUND
23
24 25
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE
EARTH
GROUND
23
24 25
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE
10-aav_uvcm-001-V0
2-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa148cp

Table of Contents