Page 1
Record the model and serial numbers before installing the Aga ventilation hood. Both numbers are listed on the rating plate, located on the left wall of the hood shell.
Important Safety Instructions To Reduce the risk of injury, please observe the instructions provided Prevent Injury to Persons in the Event For general ventilating use: observe of a Range Top Grease Fire. the following. 1. Local building codes may require the use of make-up 1.
Installation Precautions The high degree of craftsmanship in the construction and Cotton gloves are preferable. They will protect the surface finish of your hood requires careful handling to ensure from fine scratches and eliminate finger prints. proper installation. Remove all rings, watches, belt buckles, and jackets Do not remove your hood from its carton until you are (snaps-zippers) to prevent scratch marks.
48” Models 48” Models How to Steps How to Steps Aga Vent Hood Clearances: Optional Accessories - Duct Covers: • Vent Hood to either side of cabinetry: 0” • Duct Cover - depth: 12” Cooktop to underside vent hood: 30”-36” max (76-92cm) standard heights:12”,18”,or 24”...
Overall Dimensions Dimensions 12” UPPER REVEAL DEPTH 5” 18” HEIGHT 36” 48” WIDTH 2-1/2” ELECTRICAL INLET CENTER 24” LINE 20-3/4” FRONT BACK INSTALLING HOOD AT TOP INSTALLING HOOD FROM REAR 8” Transition for 36” Models 8” Round Duct for 36” Models 10”...
(allthreads, nuts, etc.). Be sure the location will not interfere with wiring, other utilities, or structural considerations. Method 1: Ventilation Hood - Ceiling Mounted 1. Use 2x4s, Unistrut or Angle Iron, to construct the framing. The considerable weight of the hood makes this necessary.
Position screws such that damper assembly can open and close. 10. Make electrical connections.(An electrical contractor should make all electrical connections. See wiring diagram.) Method 3: Ventilation Hood - Rough-In Plate Mounted 8” or 10” round duct Transition rough-in plate...
Installation Assembly Rough-in Plate Mount Installation WARNING CAUTION Framing must be tied together and to ceiling joists to provide enough If wall framing is not available, wall structural strength to support the anchors must be used. weight of the hood and internal blower, if applicable The hood unit is shipped with the rough-in plate and Shipping Screws...
Fig. 2 Fig. 1 Mounting the In-Hood Fan Install the fan by aligning the holes on the fan to the weld studs on the rough-in plate. Tighten the fan to Fan Plate the plate using the nuts provided. Keyhole Plug the “Molex” plug on the fan to the “Molex” plug on the hood.
Electrical Connection Run power cable to installation location. Remove wiring cover, Power Supply install wire clamp, insert cable in hood through wire clamp and To Remote Fan (if used) secure by tightening the wire clamp. Connect cable into wiring box, located on rough-in plate, using wire nuts.
Installation of Grease Troughs, Filters,Lamps Grease trough location is on the underside (bottom), rear area of the hood. In the center of the space provided for the filters, insert one Hood filter on the top ledge and pull back until the bottom of the Assembly filter slips into bottom ledge.
2. Warranty applies to product only in the country in which it was purchased. 3. AGA-Heartland is not liable for any claims or damages resulting from any failure of the range hood or from service delays beyond their reasonable control.
Need help?
Do you have a question about the VENTILATION HOOD and is the answer not in the manual?
Questions and answers