Repair – Tub Removal and Repair
WM3677HW
1. Remove the back cover.
(Six screws.) Remember to drain the
water if you haven't already done it.
2. Remove the large bolt securing the
rotor. This is much easier if there is
an assistant available to hold the
drum still on the inside while
loosening the bolt.
Extreme torque is not required
when replacing the bolt;
instead use a drop of Loctite®.
(M10-1.50X75 Long Bolt)
Use extreme caution! This part
holds the motor's permanent
magnets.
p46