Feature Identification - Tripp Lite PowerVerter Owner's Manual

Dc-to-ac inverters
Table of Contents

Advertisement

Feature Identification

Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
Operating Mode Switch: controls Inverter operation. Set this
1
3-position rocker switch to "ON" to have your Inverter provide
connected equipment with AC power by converting DC power from
an attached battery. Set switch to "OFF" when not using connected
equipment to prevent battery drain. Set switch to "REMOTE" to
remotely monitor and control the Inverter with the use of an optional
remote module.
"LOAD" Indicator Lights: intuitive "traffic light" signals show
2
approximate equipment load level. See "Operation for instructions on
reading indicator lights.
"BATTERY" Indicator Lights: intuitive "traffic light" signals show
3
approximate charge level of your battery. See "Operation" for
instructions on reading indicator lights.
DC Power Terminals: connect to your battery terminals. See
4
"Battery Connection" for connection instructions.
Ground Fault Interrupter (GFCI) AC Receptacles: allow you to
5
connect equipment that would normally be plugged into a utility
outlet. Enhancing safety, they feature ground fault interrupter circuits
that trip if there is a mismatch between the line current and the
neutral current.
PV1800GFCI Rear Panel
9
CAUTION!
PV3000GFCI Rear Panel
CAUTION!
12V DC
Observe proper polarity. Reversed polarity
will blow internal fuses. See manual.
4
9
4
4
9
Observe proper polarity. Reversed polarity
will blow internal fuses. See manual.
12V DC
Resettable Circuit Breaker(s): protect your Inverter against damage
6
due to overload. PV3000GFCI model includes two separate 20-amp
circuits. See "Operation" for resetting instructions.
Remote Control Module Connector: allows remote monitoring
7
and control with an optional module (Tripp Lite model APSRM4,
sold separately or included with PV3000GFCI model). See remote
module owner's manual for connection instructions.
Battery Charge Conserver (Load Sense) Dial: conserves battery
8
power by setting the low-load level at which the Inverter
automatically shuts off. See "Operation" for setting instructions.
Multi-Speed Cooling Fan(s): quiet, efficient fans prolong equipment
9
service life.
Main Ground Lug: properly grounds the Inverter to vehicle
10
grounding system or earth ground. See "Battery Connection" for
connection instructions.
Low Battery Alarm/Shutdown (internal, not shown): automatically
detects low voltage and shuts down Inverter to preserve vehicle
battery.
Overload Alarm/Shutdown (internal, not shown): automatically
detects wattage overload on Inverter outlets and shuts down Inverter
as a protective measure.
PV1800GFCI Front Panel
5
8
LOAD
SENSE
GREATER
LESSER
LOAD
LOAD
ON
ON
OUTPUT
CIRCUIT
BREAKER
20A
PV3000GFCI Front Panel
3
1
8 3
7
2
5
10
3
7 2
1
5
BATTERY
LOAD
HI
LOW
REMOTE
MED
MED
REMOTE
OFF
ON
LOW
HI
OUTPUT
CIRCUIT
BREAKER
20A
6
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerverter pv1800gfciPowerverter pv3000gfci

Table of Contents