7. Other Functions
7.2.
Other indications
7.2.1. Centrally Controlled
˚C
TEMP.
G Displayed when operation is controlled by central controller, etc.
Restricted operations are shown below.
ON/OFF (including timer operation)
Operation mode
Set temperature
Note:
May also be individually restricted.
7.2.2. Flashing Mode Indicator
˚C
TEMP.
I When flashes continuously
Displayed when another indoor unit connected to the outdoor unit is
already operating in a different operation mode.
Match with the operation mode of the other indoor unit.
I When mode switched after display flashes
Displayed when operation mode is restricted for each season by central
controller, etc.
Use another operation mode.

8. Function Selection

Function selection of remote controller
The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when
needed.
Item 1
1. Change Language
Language setting to display
("CHANGE
LANGUAGE")
2. Function limit
(1) Operation function limit setting (operation lock) ("LOCKING
("FUNCTION
FUNCTION")
SELECTION")
(2) Use of automatic mode setting ("SELECT AUTO MODE")
(3) Temperature range limit setting ("LIMIT TEMP FUNCTION")
(1) Remote controller main/sub setting ("CONTROLLER MAIN/
3. Mode selection
SUB")
("MODE SELEC-
TION")
(2) Use of clock setting ("CLOCK")
(3) Timer function setting ("WEEKLY TIMER")
(4) Contact number setting for error situation ("CALL.")
(1) Temperature display °C/°F setting ("TEMP MODE °C/°F")
4. Display change
("DISP MODE
(2) Suction air temperature display setting ("ROOM TEMP DISP
SETTING")
SELECT")
(3) Automatic cooling/heating display setting ("AUTO MODE
DISP C/H")
˚C
ON/OFF
˚C
ON/OFF
Item 2
7.2.3. Error Codes indication
If you have entered contact number to be called in the event of a prob-
lem, the screen displays this number. (You can set this up under Func-
tion Selection of remote controller. For information, refer to section 8.)
ERROR CODE
Error Code
Indoor Unit's
Refrigerant
Alternating
Address
Display
ERROR CODE
˚C
˚C
ON/OFF
Error Code
G If the ON lamp and error code are both flashing: This means that the air
conditioner is out of order and operation has been stopped (and cannot
resume). Take note of the indicated unit number and error code, then
switch off the power to the air conditioner and call your dealer or servicer.
G If only the error code is flashing (while the ON lamp remains lit): Opera-
tion is continuing, but there may be a problem with the system. In this
case, you should note down the error code and then call your dealer or
servicer for advice.
* If you have entered contact number to be called in the event of a
problem, push the Check button to display it on the screen. (You can
set this up under Function Selection of remote controller. For infor-
mation, refer to section 8.)
Item 3 (Setting content)
• Display in multiple languages is possible
• Setting the range of operation limit (operation lock)
• Setting the use or non-use of "automatic" operation mode
• Setting the temperature adjustable range (maximum, minimum)
• Selecting main or sub remote controller
* When two remote controllers are connected to one group, one controller
must be set to sub.
• Setting the use or non-use of clock function
• Setting the timer type
• Contact number display in case of error
• Setting the telephone number
• Setting the temperature unit (°C or °F) to display
• Setting the use or non-use of the display of indoor (suction) air tempera-
ture
• Setting the use or non-use of the display of "Cooling" or "Heating" display
during operation with automatic mode
ON lamp
ON/OFF
(Flashing)
Indoor Unit No.
When the Check button is pressed:
CALL:XXXX
XXX:XXX
ON/OFF