O V E R A L L D I M E N S I O N S
895
B = Adjustable height ( reg. 116/170mm ).
These instructions address appropriate installers and serve as
a guide for installation, adjustment and maintenance in conformity
with the laws and regulations in force.
WARNING: This appliance is not suitable to be installed on
Make sure that the wall surface behind the Cooker is non-
combustable (will not catch fire). A plastered or tiled wall is ideal.
600
Where a painted surface is adjacent, a fire retardent paint surface
is recommended. Wallpaper, wood, or fabric should not be used
behind or next to the cooker.
Any adjoining wall surface situated within 200mm from the edge
of any hob burner must be suitable non-combustible material for
a height of 150mm for the entire length of the hob. Any combustible
construction above the hotplate must be at least 650mm above
the maintop.
Ensure appliance is positioned following below instructions in
order to protect against overheating the surrounding surfaces.
Ensure that a power and gas supply is nearby. The Cooker should be
located carefully so that the heat produced by it has plenty of space to
escape. The diagram below shows an ideal configuration.
3
1st SECTION FOR THE QUALIFIED TECHNICIAN

INSTALLATION INSTRUCTIONS

POSITIONING
a base
min. 50 mm
min.100 mm
min. 50 mm

Advertisement