2: Mounting and Configuring the IP Camera
Condition
Flashing green (3 sec.
intervals)
Flashing green (1 sec.
intervals)
Flashing green (0.2 sec.
intervals)
Flashing green-red (1 sec.
intervals)
Flashing red (0.1 sec.
intervals)
The following power-up conditions on the system status LED are abnormal:
LED not lit when the LAN and Status LED State parameter is On (see page 31)—Check
the power supply and cabling. If power is available and the LED stays off, call Verint
Video Intelligence Solutions customer service for assistance.
Steady red LED persisting more than 10 seconds—There is an internal error that
prevents the device from starting normally. Power down the device, wait 30 seconds,
then power it up. If the condition persists, call Verint Video Intelligence Solutions
customer service.
Flashing green-red LED not during a firmware update—The device is in backup mode;
you will need to perform a firmware update using a serial connection. The device
requires a new firmware with a serial connection.
18
Indication
The firmware has started, but the device is not connected to
the network.
The firmware has started, the device is connected to the
network, but no video data is transmitted.
The firmware has started, the device is connected to the
network, and video data is transmitted.
The device is undergoing a firmware update or is in backup
mode.
The device is being identified.