8. TROUBLESHOOTING

8-1.NO.AC.OUTPUT
8-1-1.CHECKING.STATOR
(1) Remove control panel and disconnect stator wires at the connectors .
(2) Measure the resistance between terminals
on stator leads .
Refer to Table of Section 6-3 STATOR for
normal resistance .
If stator is faulty, replace it with a new one .
(3) Check the insulation resistance between
stator core and each stator lead using a
megger tester .
If insulation is bad, replace stator with a
new one .
8-1-2.CHECKING.ROTOR
1) Field coil
Remove the brush holder and measure
resistance between the slip rings . Refer to
Section 6-4 ROTOR ASSEMBLY for normal
resistance .
NOTE : I f the circuit tester is not sufficiently
accurate, it may not show the values
given and may give erroneous readings.
Erroneous reading will also occur when
there is a wide variation of resistance
among coil windings or when
measurement is performed at ambient
temperatures different from from 20°C
(68°F).
SLIP RING
ROTOR
- 49 -
CIRCUIT TESTER
(Resistance)
MEGGER TESTER
CIRCUIT TESTER
(Resistance)