NOTE: For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. (See the Internal Programming Jumper section of this guide.) P/N 8617
or a standard automotive SPDT relay must be used on the H1/2 light flash output harness wire.
H1/3 WHITE/BLUE (-) channel 3 output
This wire provides a (-) 200 mA output whenever the transmitter code controlling Channel 3 is received. This
output will continue as long as that transmission is received. Use for options such as 551T Valet® Start system,
529T or 530T power window controllers, etc.
IMPORTANT! Never use this wire to drive anything except a relay or a low-current input! The tran-
sistorized output can only provide 200 mA of current, and connecting directly to a solenoid, motor,
or other high-current device will cause it to fail.
H1/4 BLACK/WHITE (-) interior light illumination output
Connect the H1/4 BLACK/WHITE wire to an optional relay for interior light illumination (p/n 8617 or standard
automotive SPDT relay).
IMPORTANT! This output is only intended to drive a relay. It cannot be connected directly to
the domelight circuit, as the output is not able to support the current draw of one or more
light bulbs.