Page 19
Diagram of CZ Infrared
Parts List
A
Cover
B
Case
C
Heater Core
D
Grill
E
Fan Holder
F
Fans
G
Insulator Cover
H
High Limit Reset
I
Top Case Bracket
Customer/Warranty Service: (800) 595-9605
Heater CZ-1000F
™
J
Bottom Case Bracket
K
Ceramic Heating Element
L
Fan Transformer
M
Baffle
N
Heat Resistant Insert
O
Solid state relay
P
Connection Plate
for ductwork to distribute the heat through the various rooms of a home or
office. Eliminating the ductwork also eliminates the dust pollen and mold that
accumulates in a conventional heat duct system.
Energy Saving Benefits
Energy Saving Benefits
Energy Saving Benefits
Infrared heat waves are transferred more quickly throughout the room due to
their shorter wave length. The results are impressive because it requires less
energy to heat the room evenly with infrared heat than with radiant heating
sources. This makes infrared heat a highly cost‐efficient solution for heating
your home.
If you really want to save on energy costs, the cost of heating with CZ Infrared™
heat is going to be spectacular. Usually a 50% savings over conventional heat
sources is achieved, even with other electrically generated heating systems.
As much as 65% savings is achieved if replacing heating oil or other fossil fuel
heating systems.
Quiet Operation
CZ Infrared™ heating systems operate virtually silently at over 150 cubic feet
per minute per heating unit. They are quieter than forced air systems and they
do not have the typical cracking and popping experienced when heating with
baseboard heaters. Compared to conventional in‐wall heaters there is no
comparison to the quiet operation of the CZ Infrared™ fan system. Fans are
rated at 16 dB compared to 65 dB of conventional in‐wall heating systems.
Better Heat Distribution
The nature of the infrared wave allows the heater to be installed higher on the
wall than conventional in‐wall heater systems without compromising the
transfer of the heat to the floor. The advantage of the higher installation on
the wall guarantees that furniture and other obstructions to the airflow from
the heater are eliminated. Child tampering is also eliminated.
Even distribution of the infrared wave is also assured since the air space above
the furniture is virtually unrestricted. When conventional heat sources are
vented through the ceiling to economics and save on construction costs, the
heat remains on the ceiling and must be pushed to floor with ceiling fans. This
is not required with infrared heat.
©2009 EarthWise Technologies, Inc
Page 4