Model Number Description; Optional Equipment - American Standard ALLEGIANCE 10 Product Data

Allegiance 10 models 7a0018-060 split system cooling 1—5 ton
Table of Contents

Advertisement

PRODUCT DATA
American Standard Inc., Tyler, TX 75711-9010
Outdoor Product Type
Split Cooling - 7A, 7B, 7C
Split Heat Pump - 6H, 6C
Efficiency
0 - 10 SEER
1 - 11 SEER
2 - 12 SEER
4 - 14 SEER
Primary Capacity
Example: 042 = 42 MBTUH = 4 Tons
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [ ] indicates accessories included).
Indoor Thermostats — Prog. Electronic Setback 3 Heating/2 Cooling ................................................................................... ASYSTAT620 [ ]
Prog. Electronic Setback 1 Heating/1 Cooling ................................................................................... ASYSTAT621 [ ]
Cooling Only with Fan Switch ............................................................................................................ ASYSTAT603 [ ]
Heating/Cooling — Vertical ................................................................................................................ ASYSTAT604 [ ]
Heating/Cooling — Horizontal ............................................................................................................ ASYSTAT605 [ ]
Manual 2 Heating/1 Cooling ............................................................................................................... ASYSTAT606 [ ]
Thermostat Locking Cover ................................................................................................................... BAY28X190 [ ]
Outdoor Thermostat ............................................................................................................................................................... TAYSTAT250A [ ]
Evaporator Defrost Control .......................................................................................................................................................... AY28X079 [ ]
Indoor Fan Delay Relay Kit ........................................................................................................................................................ BAY24X045 [ ]
Humidistat ................................................................................................................................................................................. ASYSTAT625 [ ]
5 Minute Delay Relay1 ......................................................................................................................................................... TAYASCT501A [ ]
Quick Start Kit (7A0018,024,036,042A) .............................................................................................................................. BAYKSKT250A [ ]
Quick Start Kit (7A0048-60B) .............................................................................................................................................. BAYKSKT252A [ ]
Rubber Isolators ........................................................................................................................................................................ BAYISLT100 [ ]
Crankcase Heater Kit (7A0048B)2 ..................................................................................................................................... BAYCCHT200A [ ]
Crankcase Heater Kit (7A0060B)2 ..................................................................................................................................... BAYCCHT201A [ ]
1 Do not use with programmable thermostats.
2 When field inner connecting lines exceed 60 linear ft. of length consult refrigerant piping software (Pub. No. 12-3312-01).
BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)
5/8" ODM (90° bend, one end), 5/8" & 1/4" tubing ............................................................................................................. TAYREFLN1__* [ ]
3/4" ODM (90° bend, one end), 3/4" & 5/16" tubing ........................................................................................................... TAYREFLN2__* [ ]
7/8" ODM (90° bend, one end), 7/8" & 3/8" tubing ............................................................................................................. TAYREFLN3__* [ ]
1-1/8" ODM (90° bend, one end), 1-1/8" & 3/8" tubing ....................................................................................................... TAYREFLN4__* [ ]
*Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number.
Example: TAYREFLN220.
Low Ambient
Cooling
FCCV Accutron
Thermal Expansion Valve (TXV)
4
Model Number
Description
1
2
3
4*
5
7
A
0
0
4

OPTIONAL EQUIPMENT

LOW OUTDOOR AMBIENT COOLING
Manufactured
55°F
45°F
DATA SUBJECT TO CHANGE WITHOUT NOTICE
6
7
8
9
10
2
A
1
0
0
Voltage/Power Supply
1 - 200-230 Volts 1 Phase
3 - 208-230 Volts 3 Phase
4 - 460 Volts 3 Phase
Major Design Modification
As
11
12
A
0
Product/Service/Parts
Minor Design Modifications
Secondary Functions
Evaporator
Defrost Control
40°F
30°F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents