7A0042A100A - American Standard ALLEGIANCE 10 Product Data

Allegiance 10 models 7a0018-060 split system cooling 1—5 ton
Table of Contents

Advertisement

PRODUCT DATA
American Standard Inc., Tyler, TX 75711-9010
OUTDOOR UNIT 12
POWER CONNS. — V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
}
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
NOISE RATING (DECIBELS) 2
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN — TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT - CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
SEER (BTU/WATT-HR.)
EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
SEER (BTU/WATT-HR.)
See page 22 for combinations with Auxiliary Devices.
14
General Data —

7A0042A100A

200/230/01/60
DURATION™
1 - 1
200/230/1/60
19.0 - 105
PROPELLER
18 - 1
DIRECT - 1
2685
1 - 1/4
1075
200/230/1/60
1.50
SPINE FIN™
1 - 24
12.47
5-LBS., 6-OZ.
YES
0.077
H X W X D
27-3/8 X 31-1/2 X 27-5/8
SEE OUTLINE DWG.
CONDENSING UNIT WITH COOLING COILS
CCBB42A4ACC
CCBB48A4ACC
FIXED ORIFICE
FIXED ORIFICE
39000
39000
25800
26300
1200
1250
4.22
4.24
10.05
10.00
TXA036C4
TXA037C4
CHG TO 77
CHG TO 77
39000
40000
25700
27100
1200
1350
4.22
4.32
10.05
10.00
TXA060C5
TXA061C5
TXV-B
TXV-B
41500
42000
30300
30600
1555
1575
4.46
4.47
10.00
10.10
DATA SUBJECT TO CHANGE WITHOUT NOTICE
7A0042A100A
1 CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR-CONDITIONER
EQUIPMENT CERTIFICATION PROGRAM, WHICH IS BASED ON A.R.I.
25
STANDARD 210/240.
40
40
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
80
NO
NO
NO
3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE. ONLY USE
HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR -
60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT.
FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE
PUB. NO. 12-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE
AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM
3/8
BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE
SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS.
7/8
YES MEANS QUICK START KIT COMPONENTS.
3/8
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.
212
194
CCBC48A4ACC
CUBB42A4ACC
FIXED ORIFICE
FIXED ORIFICE
40500
39000
28900
25800
1505
1200
4.45
4.22
10.00
10.05
TXA042C4
TXA043C4
CHG TO 77
CHG TO 77
40000
40500
26800
27900
1250
1400
4.30
4.38
10.00
10.05
TXC035C4
TXC035D4
CHG TO 77
CHG TO 77
37200
37200
23400
23400
1100
1100
4.09
4.09
10.00
10.00
SPLIT SYSTEM
CUBB48A4ACC
CUBC48A4ACC
FIXED ORIFICE
FIXED ORIFICE
39000
40500
26300
28900
1250
1505
4.24
4.45
10.00
10.00
TXA048C4
TXA049C4
CHG TO 77
CHG TO 77
41000
41500
28200
30000
1350
1555
4.39
4.49
10.10
10.00
TXC036C4
TXC036D4
CHG TO 77
CHG TO 77
39000
39000
25700
25700
1200
1200
4.22
4.22
10.05
10.05
TXA035C4
CHG TO 77
37200
23400
1100
4.09
10.00
TXA050C4
CHG TO 77
41500
30000
1555
4.49
10.00
TXC036E5
TXV-B
41000
28100
1350
4.34
10.15