Service Request Number (Srn) Table For Sp Switch Adapters - IBM RS/6000 SP Service Manual

Sp switch
Hide thumbs Also See for RS/6000 SP:
Table of Contents

Advertisement

SP Switch function (MAP 0620)
v If yes:
a. An SRN was obtained from diagnostics.
b. Use the following SRN table (Table 1-9) to continue service.
c. After using Table 1-9, go to "Step 0620-012" on page 1-26.
v If no:
a. The diagnostics did not detect a problem, therefore the problem is in SP Switch.
b. Go to "Step 0620-041" on page 1-35.
Table 1-9. Service Request Number (SRN) table for SP Switch adapters
Service Request Number
762-200
through
762-299
762-2A0
through
762-2A9
762-300
through
762-399
762-400
through
762-499
762-500
through
762-599
762-600
through
762-699
762-700
through
762-799
762-800
through
762-899
762-900
through
762-999
762-Ax3
(See note)
762-Ax4
(See note)
763-1xx
(See note)
1-24
RS/6000 SP: SP Switch Service Guide
SRN
source
Failing component(s)
D
762-100
through
762-199SPS adapter
software
system or I/O planar
D
external clock
SPS adapter
(wrap plug)
D
SPS adapter
D
SPS adapter
system or I/O planar
D
SPS adapter
software
D
SPS adapter
D
SPS adapter
D
SPS adapter
D
SPS adapter
D
SPS adapter
I/O planar
data cable
D
SPS adapter
(terminator)
D
SPS data cable
(wrap plug)
D
SPS MX adapter
software
system or I/O planar
Description
Problem detected with device or
device data corrupted. You may
need to reinstall "ssp.css" code.
Problem detected with external
clock.
Problem detected with internal
clock.
Problem detected with POS
registers.
TBIC test failed.
SRAM test failed.
Microprocessor test failed.
Interrupt test failed.
FIFO test failed.
DMA engine test failed.
Card wrap test failed.
Cable wrap test failed.
Problem detected with a device
or device data corrupted.
Note: You may need to reinstall
ssp.css software.

Advertisement