Auxiliary Harness (H2) Wire Connection Guide - Avital 2200 Installation Manual

Directed electronics
Hide thumbs Also See for 2200:
Table of Contents

Advertisement

auxiliary harness (H2) wire connection guide

______
H2/1
______
H2/2
______
H2/3
H2/1 BLUE (-) 200 mA second unlock output
This output is used for progressive door unlock. A progressive unlock system unlocks the driver's door when the
unlock (disarm) button is pressed and unlocks the passenger doors if the unlock (disarm) button is pressed
again within 15 seconds after unlocking the driver's door. The BLUE wire outputs a low current (-) pulse on the
second press of the unlock button of the transmitter. This negative unlock output is used to unlock the pas-
senger doors.
NOTE: The second unlock output feature is not available if the double pulse unlock feature is turned on.
The following diagrams show how to wire progressive door locks on some of the most common door lock systems.
Type A (+) polarity system: Wire relays as shown.
8
BLUE
BROWN/BLACK
BLACK/WHITE
INPUT TO ON-BOARD INTERIOR LIGHT ILLUMINATION RELAY #87
(-) 200mA SECOND UNLOCK
(-) 200mA HORN HONK OUTPUT
© 2001 Directed Electronics, Inc. Vista, CA