Storage
The generator set should be started at least once every 14 days and allowed to run for at least 20 minutes.
For longer term storage, please follow these guidelines.
1.
Allow the engine to cool completely before storage.
2.
Clean the engine according to the instructions in the Maintenance section.
3.
Turn the ENGINE SWITCH to OFF position.
4.
Close the manual shutoff valve on the LPG cylinder or on the NG pipeline and disconnect from
the generator set.
5.
Drain all the oil.
6.
Remove the spark plug and pour about 15g (about 0.5 ounce) of oil into the cylinder. Crank the
engine slowly to distribute the oil and lubricate the cylinder.
7.
Re-attach the spark plug.
8.
Store the unit in a clean, dry area, out of direct sunlight.
Transportation
1. Drain all remained oil in the crankcase.
2. Package generator set according factory state.
!
Caution
Never lay the generator set with upside down.