LED Combinations

The following table shows the kind of activity that occurs in various LED
illumination combinations:
Link LED
100 LED
On
Off
On - Slow Blink
Off
On
On
On - Slow Blink
On - Slow Blink
Off
Off

Reset Button

This button is used to reset the hub while it is powered on. This action clears
any temporary error conditions that may have occurred, restarts the hub and
executes the hub self test. A typical instance of where you might use the Reset
button is in the event of a hub malfunction or error condition.

Back of the Hubs

Power Connector

The 10/100 hubs do not have a power switch; they are powered on when
connected to an active AC power source. The hubs automatically adjust to
various voltages (depending on the country) between 100-127 and 200-240
volts and either 50 or 60 Hz. There are no voltage range settings required.
AC Power
Connector
Introducing the HP ProCurve 10/100 Hubs
What is Happening
The port is operating at 10Mbps.
The port is operating in 10Mbps mode, but has
been partitioned due to excessive collisions.
The Fault LED will also blink.
The port is operating at 100Mbps.
The port is operating in100Mbps mode, but has
been partitioned due to excessive collisions.
The Fault LED will also blink.
The port does not detect another device.
Cooling vents - make sure
these are not obstructed for
proper hub operation
Back of the Hubs