Toshiba RAS-13NKHD-E Service Manual page 16

Split wall type
Table of Contents

Advertisement

4-3. Outdoor Unit (RAS-10UAH-E3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
4-4. Outdoor Unit (RAS-07UAH-E3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
Type
Output (Rated) 750 W, 2 poles, 1 phase, 220 − 240 V, 50Hz
PH120T1-4C
Winding resistance ( )
(at 20 C)
Output (Rated) 20 W, 6 poles, 1 phase, 220 − 240 V, 50Hz
HF-240-20B or
Winding resistance ( )
SKF-240-20B
(at 20 C
DS451155BPQC AC 450 V, 1.5μF
DS371256CPNB
AC 370 V, 25μF
JMRA99269-9200 U/T : 6.8A (90 C), OPEN : 135±5 C, CLOSE : 69±11 C
Type
Output (Rated) 560W, 2poles, 1 phase, 220 − 240V, 50Hz
PH80T1-4C
Winding resistance (Ω)
(at 20°C)
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-20B or
Winding resistance (Ω)
SKF-240-20B
(at 20°C)
DS451155CBPQC AC 450V, 1.5μF
DS371256CPN
AC 370V, 25μF
JMRA99208-9201 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
− 15 −
FILE NO. SVM-04022
Specifications
Ω
°
Ω
°
387.3 or 235.2
°
Specifications
387.3 or 235.2 466.2 or 260.1
C-R
C-S
4.53
8.73
Red-Black
White-Black
466.2 or 260.1
°
°
C-R
C-S
4.80
8.37
Red-Black
White-Black