4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13NKHD-E, RAS-10NKHD-E, RAS-07NKHD-E)
No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching transformer
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB01)
8
Capacitor (C03)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Louver motor
12
Relay (Comp., RY01)
13
Relay (Fan, RY03)
Relay (Solenoide, RY04)
14
4-2. Outdoor Unit (RAS-13UAH-E3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Overload relay
5
Type
SKF-220-20-4A-1
SWT-77
TMP87CM40AN
LC*SS11V-06270
D3SBA60
KHM400VSSN47M225
BET6.3A
15G561K320
MP24Z
DI1U
G5N-1A
G5N-1A
Type
Output (Rated) 1100 W, 2 poles, 1 phase, 220 − 240 V, 50Hz
PH170T2-4L2
Winding resistance ( )
(at 20 C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 − 240 V, 50Hz
HF-240-42A
Winding resistance ( )
(at 20 C)
DS451155CBPQC AC 450 V, 1.5μF
DS371356CPNB
AC 370 V, 35μF
RAT00AL
Bimetal of current cantrol :
U/T : 8.6A (100°C), OPEN : 150±5°C, CLOSE : 70±11°C
Bimetal of temperature control :
OPEN : 130±5°C, CLOSE : 75±15°C
– 14 –
Specifications
AC Motor with 150°C thermo fuse
10kΩ at 25°C
10kΩ at 25°C
27mH, 600mA
4A, 600 V
47μF, 400 V
T6.3A, 250VAC
560 V
12VDC
Rating 25A/AC250 V, 12VDC
Rating 3A/AC250V, 12VDC
Rating 3A/AC250V, 12VDC
Specifications
Ω
°
Ω
°
FILE NO. SVM-04022
C-R
C-S
2.22
3.04
Red-Black
White-Black
176.2
290.5