Download Print this page
Perfect Aire PMP50 User Manual

Perfect Aire PMP50 User Manual

50 pint dehumidifier with ejector pump

Advertisement

(50 PINT)
DEHUMIDIFIER
With Ejector Pump
USER MANUAL
FOR MODEL:
PMP50
Before using your dehumidifier,
please read this manual carefully
and keep it for future reference,
along with your receipt.
Your Source for Home Comfort

Advertisement

loading
Need help?

Need help?

Do you have a question about the PMP50 and is the answer not in the manual?

Questions and answers

Janet K Black
July 1, 2025

what is the part number for the Perfect Aire PMP50 humidity sensor?

Subscribe to Our Youtube Channel

Summary of Contents for Perfect Aire PMP50

  • Page 1 Your Source for Home Comfort (50 PINT) DEHUMIDIFIER With Ejector Pump USER MANUAL FOR MODEL: PMP50 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt.
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..................2 IDENTIFICATION OF PARTS................3 DEHUMIDIFIER FEATURES ................4 OPERATING INSTRUCTIONS ................6 CARE AND MAINTENANCE ................10 TROUBLESHOOTING TIPS ................11 This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications: WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4: Identification Of Parts

    IDENTIFICATION OF PARTS Rear Front  Continuous drain hose outlet  Control panel  Caster  Air intake grille  Power cord and plug  Air outlet grille  Band (used only when storing the unit)  Air filter (behind the grille) ...
  • Page 5: Dehumidifier Features

    DEHUMIDIFIER FEATURES NOTE: The control panel of the unit you purchased may be slightly different based on the model. Clean filter High fan indicator light indicator light Filter Turbo Filter Continuous Bucket full operation on Full Cont. indicator light indicator light Pump Auto defrost Pump...
  • Page 6 DEHUMIDIFIER FEATURES (CONTINUED) ERROR AND PROTECTION CODES: EC - Unit Malfunction - Please make sure the AS - Humidity Sensor Error - Unplug the unit and plug temperature of the environment is suitable for it back in. If error repeats, call customer service. the proper operation of the unit.
  • Page 7: Operating Instructions

    OPERATING INSTRUCTIONS POSITIONING THE UNIT A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. ●...
  • Page 8 OPERATING INSTRUCTIONS (CONTINUED) REMOVING THE COLLECTED WATER There are three ways to remove collected water: ● Use the bucket. ● Continuous draining - gravity takes water down hose into drain. ● Pump Draining - bucket fills, then pump drains water vertically, up to 16 ft. OPTION 1: Use the bucket ●...
  • Page 9 OPERATING INSTRUCTIONS (CONTINUED) OPTION 2: Continuous Draining Water can be automatically emptied into a floor drain by attaching Adaptor A Drain hose a water hose (Inner Diamater ≥ 5/16”, not included) with a female threaded end (Inner Diameter: M-1”, not included) to the unit using adaptor A (included) and the short drain hose (included).
  • Page 10 OPERATING INSTRUCTIONS (CONTINUED) OPTION 3: Pump Draining Fig.13 Water can be automatically emptied into a floor drain or a Plastic cover suitable drainage facility by attaching the pump drain with a pump drain hose. (Outer Diameter = 1/4”, supplied.) Adaptor A with Short Hose ●...
  • Page 11: Care And Maintenance

    CARE AND MAINTENANCE Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. 1. Clean the grille and case. ● Use water and a mild detergent. Do not use bleach or abrasives. ● Do not splash water directly onto the main unit. Doing so may cause an electrical shock, the insulation to deteriorate, or the unit to rust.
  • Page 12: Troubleshooting Tips

    TROUBLESHOOTING TIPS Before calling for service, please review the chart below. Issue Possible Solutions Turn off unit and unplug 4-6 hours. Plug unit back in. Run in normal mode (no Turbo fan, not on Continuous operation) and set humidity level to no more than 5% lower humidity than what the display reads for the room humidity.
  • Page 13 TROUBLESHOOTING TIPS (CONTINUED) Before calling for service, please review the chart below. Question Possible Solutions Be sure unit is not too large or too small for the area of the room. Allow enough time for unit to remove moisture. If set on Continuous Mode, de-select button and set unit to an appropriate humidity setting. If humidity in room is above the set humidity, then unit will be running.
  • Page 14 Your Source for Home Comfort Distributed by: Perfect Aire, LLC 5151 Belt Line Rd. Suite 878 Dallas, TX 75254 877-365-6274 www.perfectaire.us Specification and performance data is subject to change without notice. Printed in PRC...