Download Print this page
Perfect Aire 2PFD22 Owner's Manual
Hide thumbs Also See for 2PFD22:
  • Faq (5 pages)

Advertisement

OWNER'S MANUAL
DEHUMIDIFER

Advertisement

loading

Summary of Contents for Perfect Aire 2PFD22

  • Page 1 OWNER’S MANUAL DEHUMIDIFER...
  • Page 2: Table Of Contents

    CONTENTS Safety Precautions Page 2 Identification of Parts Page 5 Operating Instructions Page 7 Care and Maintenance Page 14 Troubleshooting Tips Page 15 MODEL 2PFD22 2PFD35 2PFD50 2PFDP50 Page 1...
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Read these safety precautions before installation and operation. For your safety, it is important that you read and follow the instructions in this manual to minimize the risk of personal injury, fi e or electrical shock. This symbol shows that this appliance uses a flammable refrigerant.
  • Page 4 CAUTION • This dehumidifier is intended for indoor esidential us only and should not be used for commercial or industrial applications. Do not use outdoors • Do not place the unit near a heat source or other heat generating appliances such as clothes dryer, heater or radiator •...
  • Page 5 WARNING: FOR YOUR SAFETY • The dehumidifier should not be sto ed in a room with continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater) • Do not pierce or burn this dehumidifier •...
  • Page 6: Identification Of Parts

    IDENTIFICATION OF PARTS BEFORE YOU BEGIN NOTE: All the illustrations in the manual are for explanation purpose only. Your dehumidifier may be slightly different. The design specifications are subject to change without prior notice. Consult with the customer service for details. The most up-to-date versions of the manual can be found on the service website. Please check for the latest version.
  • Page 7 POSITIONING THE UNIT This dehumidifier should not be used for comme cial or industrial applications. Place the dehumidifier on a smooth, level floor s ong enough to support the unit with a full bucket of water. For good air circulation, allow at least 8 inches of air space on all sides of the unit and a minimum of 16 inches of air space at the air outlet (Fig.
  • Page 8: Operating Instructions

    Note: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly diffe ent according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail. 2PFD22, 2PFD35, 2PFD50 2PFDP50 FILTER Button COMFORT Button •...
  • Page 9 CONTINUE button TIMER button • Press to activate the continuous dehumidifying Timer button is used in conjunction with the operation. (Humidity Control) buttons to initiate the • If the CONT. mode is selected the unit will Auto start and Auto stop feature. continue to dehumidify and will not be Setting the Timer controlled to a specific humidity setting.
  • Page 10 • Press the TIMER button again the timer On POWER button indicator light illuminates. This indicates the auto start program is initiated. • Press to turn the dehumidifier on and o • Press or hold the button to change the desired start time by 0.5hour increments, up to OPTIONAL FEATURES (Only available on SOME 10 hours, then at 1 hour increments from 10 to 24...
  • Page 11 OTHER FEATURES Bucket Full Light Auto Shut Off FULL The Full indicator light will be illuminated when The dehumidifier shuts off when the bucket is full the bucket is full and ready to be emptied or if the or when the bucket is removed or is not replaced bucket was not put back in place correctly.
  • Page 12 REMOVING THE COLLECTED WATER There are three ways to remove collected water: Using the bucket • If the unit is off, and the bucket is full, the Full indicator light will illuminate • If the unit is on and the bucket is full, the compressor and the fan will turn off, the Full indicator light will light will illuminate and the LED display will show P2.
  • Page 13 Continuous draining • Water can be automatically emptied into a floor drain by attaching a drain hose (ld≥Φ5/16′′, not included) with a female threaded end (ID:M=1′′, not included) to the drain outlet at the back of the dehumidifier (See Fig. 8 •...
  • Page 14 Note: The pump may make a noticeable sound for 3~5 minutes on startup. It is a normal phenomenon. Note: The pump operation light will blink will at 1Hz if there is an operational failure of the pump. Please turn off the unit and unplug the power. Check the following things: •...
  • Page 15: Care And Maintenance

    CARE AND MAINTENANCE Turn the dehumidifier off and unplug it from the wall outlet before cleaning. • Use water and a mild detergent. Do not use bleach or abrasives. • Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • Page 16: Troubleshooting Tips

    TROUBLESHOOTING TIPS Before calling for service, review the chart below. Problem What to check Unit does not start • ·Make sure the dehumidifier s plug is pushed completely into the outlet. • Check the house fuse/circuit breaker box. • Dehumidifier has eached its preset level or bucket is full. •...
  • Page 17 Perfect Aire, LLC 5401 Dansher Road Countryside, IL 60625 1020_M398 844-4PA-AIRE | 844-472-2473 www.perfectaire.us Printed in China...

This manual is also suitable for:

2pfd352pfd502pfdp50