Built-In Fireplace Installation - Empire Comfort Systems VFL20IN3 Installation Instructions And Owner's Manual

Loft vent free fireplace insert
Hide thumbs Also See for VFL20IN3:
Table of Contents

Advertisement

In planning the installation for the fireplace, it is necessary to
determine where the unit is to be installed and whether optional
accessories are desired. Gas supply piping should also be planned
at this time.
The fireplace can be mounted on any of these surfaces:
1. A flat hard combustible or non-combustible surface.
2. A raised platform of combustible or non-combustible material.
3. Four (4) corners of the fireplace so contact is made on all four
perimeter edges on the bottom of the unit.
(Example: Four (4) concrete masonry blocks.)
If the fireplace is installed directly on carpeting, tile or other
combustible material other than wood flooring, it should be installed
This unit is designed to be installed in a zero-clearance enclosure.
This means the combustible material can come in contact with the
firebox.

Built-In Fireplace Installation

Built-in installation of this fireplace involves installing the
fireplace into a framed-in enclosure. This makes the front of the
fireplace flush with a wall.
Frame in rough opening. Use dimensions show in Figure 3 for a
conventional rough opening. Use dimensions shown in Figure 4
for corner rough opening. Use Figure 5 for an elevated installation.
Be sure to provided support to the bottom of the fireplace. Be sure
to provide gas line for fireplace and electrical power for optional
blower assembly.
Rough Opening for Installing in Wall
1" TO 6" FROM BACK
25mm TO 152mm
ELECTRICAL RECEPTACLE
Figure 3
VFL20IN
VFL28IN
Page 12
BUILT-IN FIREpLACE INSTALLATION
Rough Opening for Installing in Corner
C
A
13 3/4"
(349.3 mm)
16 3/4"
(425.5 mm)
on a metal or wood panel extending the full width and depth of the
unit.
At this point, you should have decided what components to include
in your installation, and where the fireplace is to be located. If this
has not been done, stop and consult your dealer for assistance
with this planning.
1.
Gas line connections must be made at this time. When
facing the appliance, the gas supply will enter on the right-
hand side. See "Gas Supply" page 17 to 18.
2. Insert fireplace into enclosure. Attach to wall with screws
through holes on cabinet sides.
3. Level firebox. See "Positioning, Leveling and Securing Insert"
on Page 10.
4. Finished wall surface will be flush to the leading edge of fire-
place top and sides.
5. If used, the surround panel assembly is installed after the fire-
place has been installed with all the gas and electrical con-
nection completed. Refer to instructions included with the sur-
round panel kit.
6. Installation of built-in fireplace is completed.
25 5/8"
650.9mm
B
51 1/4" (1301.8mm)
Figure 4
B
C
27 3/4"
19 1/4"
(704.9 mm)
(489 mm)
30 1/2"
22 1/2"
(774.7 mm)
(571.5 mm)
Rough Opening for Elevated Installation
1" TO 6" FROM BACK
25mm TO 152mm
ELECTRICAL RECEPTACLE
A
Figure 5
D
36 1/4"
(920.8 mm)
36 1/4"
(920.8 mm)
C
6" MINIMUM
28040-3-0511