INTERMITTENT pILOT REMOTE ELECTRONIC IGNITION AND
AUTOMATIC OpERATION
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
SETTING THE ELECTRONICS CODE
Notice: The remote control and receiver are pre-programmed at
the factory. However, if for some reason they do not communicate
to each other, follow these steps to re-program.
Radio Frequency Remote
A code is selected automatically for all Mertik Maxitrol electronics
from among 65,000 random codes available. The receiver has to
learn the code of the handset:
Press and hold the receiver's reset button (see figure 23) until
you hear two (2) beeps. After the second, longer beep, re-
lease the reset button.
Within the subsequent 20 seconds press the (small flame)
button on the remote handset until you hear an additional long
beep confirming the code is set.
Notice: This is a one time setting only, and is not required when
changing the batteries in the remote or receiver.
Figure 24
TO TURN ON AppLIANCE
When pilot ignition is confirmed, motor turns automatically to
maximum flame height.
Turn MANUAL knob to the ON, full counterclockwise
position (See Figure 25).
Place ON/OFF switch (if equipped) in (ON position).
Standard, Display, Timer/Thermostat RF Remote Handset
Simultaneously press and hold the OFF and
buttons until a short beep confirms the start sequence has
begun; release buttons.
28040-3-0511
CONTROL SYSTEM
WARNING
WARNING
(large flame)
Continuing beeps confirm the ignition is in process.
Once pilot ignition is confirmed, there is main gas flow.
After the ignition the remote will go automatically into tem-
perature control mode.
Caution: If the pilot does not stay lit after several tries, turn the
main valve knob to OFF and follow the instructions "Turn Off Gas
to Appliance" (See page 26).
Figure 25
TO TURN OFF AppLIANCE
Press OFF button on remote handset.
Notice: press
(small flame) to turn main gas to pilot gas.
ADJUSTMENT - FLAME HEIGHT
Standard, Display, Timer/Thermostat RF Remote Handsets
In standby mode: Press
height.
Press (small flame) to decrease flame height or to set ap-
pliance at pilot flame.
For fine adjustment tap the large/small flames.
Quick Flame Adjust - Display, Timer/Thermostat RF Remote
Handset
If (large flame) or (small flame) are pressed for 0.5 sec-
onds, the motor will turn the valve to high fire or pilot flame.
Caution: If the appliance will not operate, follow the instructions
"TURN OFF GAS TO APPLIANCE" (See page 26).
SETTING °C/24 HOUR OR °F/12 HOUR CLOCK
Display, Timer/Thermostat RF Remote Handsets
Press OFF and
(small flame) until display changes from
Fahrenheit/12 hour clock to Celsius/24 hour clock and vice
versa.
Figure 26
(large flame) to increase flame
Page 29