Empire Comfort Systems VFL20IN3 Installation Instructions And Owner's Manual page 30

Loft vent free fireplace insert
Hide thumbs Also See for VFL20IN3:
Table of Contents

Advertisement

INTERMITTENT pILOT REMOTE ELECTRONIC IGNITION AND
SETTING THE TIME
Display, Timer/Thermostat RF Remote Handsets
The display will flash after either:
a. Installing the battery or
b. Simultaneously pressing the
flame)
Press (large flame) to set the hour and the (small flame)
to set the minute.
Press OFF to return to manual mode or simply wait and it will
automatically return to the manual mode.
CHANGING THE MODE OF OpERATION
Briefly pressing the SET button changes the mode of operation in
the following order:
Notice: MANUAL mode can also be reached by pressing either
the
(large flame) or the (small flame).
and back to
MAN
TEMP
TEMP
Manual Flame Height Adjustment
Press (large flame) to turn on the main burner.
Press (large flame) to increase the flame height.
Press (small flame) to decrease the flame height or to go to
pilot standby position.
Notice: While pressing either button a symbol indicating trans-
mission appears on the display. The receiver confirms
transmission with a beep.
TEMP
- Daytime Temperature Mode
(appliance must be in standby mode; pilot ignited): The room tem-
perature is measured and compared to the set temperature. The
flame height is then automatically adjusted to achieve the Daytime
set temperature.
TEMP
- Nighttime Setback Temperature Mode
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the Night-
time Setback temperature. The flame height is then automatically
adjusted to achieve the Nighttime Setback temperature.
TIMER
- Timer Mode
(appliance must be in standby mode; pilot ignited):
The timer setting allows you to set two (2) burner
TEMP
and two (2) burner
For
TEMP
to operate as a thermostat, TEMP must be set at
40°F (4°C) or higher.
TEMP
If the
setting is decreased to ≤ 39°F (3.9°C), the motor
will turn the valve to the standby position in the moon times and
await the next burner
TEMP
Page 30
CONTROL SYSTEM
(large flame) and (small
TIMER
MAN
Mode
TEMP
times every 24 hours.
cycle.
Notice: The display shows the set temperature every 30 sec-
onds.
SETTING THE TEMpERATURE
Select either the
briefly pressing the SET button.
Hold the SET button until the TEMP display flashes.
Set the desired temperature with (large flame) or (small
flame).
Press OFF or simply wait to complete programming.
Notice: When the desired room temperature is SET on the
hand held remote, the burner will automatically turn on when
the room temperature drops 3 degrees Fahrenheit (F) below
the SET temperature. The remote system will turn the burner
off when the room temperature reaches 3 degrees Fahren-
heit (F) above the SET temperature. The pilot will remain lit
between burner cycles when using the thermostatic remote
control feature.
SETTING THE TIMER
MAN
Select Timer mode by briefly pressing the SET button.
Press and hold the SET button until the P1
-
is displayed and the time flashes. Set the hour by pressing the
(large flame) and set the minutes by pressing the (small
flame).
Briefly press SET button for the next burner cycle time.
Example: P1
symbol) and P2 (moon symbol).
Once all four (4) times are set, press OFF or simply wait to
complete programming.
MANUAL OpERATION
Follow appliance lighting instructions for gaining access to the gas
control and the pilot burner. Access to the pilot burner is only re-
quired for ignition with a match.
When turning main valve knob, do not force. Knob has a slip clutch
that clicks until the end stops are reached. This allows for manual
flame height adjustment as well as adjustment to pilot standby po-
sition.
STOp! Read the safety information included before proceed-
1.
ing.
2.
Turn main valve knob to the OFF, full clockwise
position.
3.
Turn MANUAL knob to the MAN, full clockwise
position.
4. Place ON/OFF switch (if equipped) in O (OFF position).
5. Wait five (5) minutes to clear out any gas. Verify that no gas
is in the area around the appliance, including near the floor. If
times
you detect gas STOp! Follow "A" in the safety information on
page 26. If no gas is present, proceed to step 6.
6.
Place ON/OFF switch in (ON position).
TEMP
MODE or the
(moon symbol) continue through P2
TEMP
MODE by
(sun symbol)
(sun
28040-3-0511