Parameter
Oneway Current Data Length
Handshake Max Interval
Handshake Max Data Length
Handshake Current Data Length 00BF R/W
Handshake Retry Number
22

Patch Parameter

The main function of patch parameters is to configure the settings of the sound source of a device.
22.1

Master EQ Parameter

These parameters configure the Master EQ settings.
Parameter ID
R/W
Block
Low Freq
00A0 R/W 55-0:0
Low Gain
00A1 R/W
Mid1 Freq 00A2 R/W
Mid1 Gain 00A3 R/W
Mid2 Freq 00A4 R/W
ID
R/W
Block
Size Array
00BC R/W
14
00BD R/W
14
00BE
R
14
14
00C0 R/W
7
Size Array Min-Def-Max Description
7
01
00-00-0C
0...200Hz
1...400Hz
2...800Hz
3...50Hz
4...63Hz
5...80Hz
6...100Hz
7...125Hz
8...160Hz
9...250Hz
10...315Hz
11...500Hz
12...630Hz
7
01
00-0C-18
-12 - 0 - +12
7
01
00-00-13
0...1.0kHz
1...1.3kHz
2...1.6kHz
3...2.0kHz
4...2.5kHz
5...3.2kHz
6...4.0kHz
7...5.0kHz
8...100Hz
9...125Hz
10...160Hz
11...200Hz
12...250Hz
13...315Hz
14...400Hz
15...500Hz
16...630Hz
17...800Hz
18...6.3kHz
19...8.0kHz
7
01
00-0C-18
-12 - 0 - +12
7
01
00-04-13
0...1.0kHz
Min-Def-Max
Description
01
0000-0080-3FFF Current memory size value (bytes) of
transfer data included in one packet
during One-way Bulk Dump send by
Instrument
01
0000-0800-3FFF Maximum allowable message wait time
(msec) during Handshake Bulk Dump
receive by Instrument
01
0000-0080-3FFF Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump
send/receive by Instrument
01
0000-0080-3FFF Maximum memory size value (bytes) of
transfer data included in one packet
during Handshake Bulk Dump send by
Instrument
01
00-03-7F
Number of retries after error
generation during Handshake Bulk Dump