IBM 4.6.x User Manual page 114

Ibm user guide adapter for siebel ebusiness applications 4.6.x
Table of Contents

Advertisement

PollEndTime
The PollEndTime property specifies the time to stop polling the event queue. The
format is HH:MM, where HH is 0 through 23 hours, and MM represents 0 through 59
minutes.
You must provide a valid value for this property. The default value is HH:MM
without a value, and it must be changed.
If the adapter runtime detects:
v PollStartTime set and PollEndTime not set, or
v PollEndTime set and PollStartTime not set
it will poll using the value configured for the PollFrequency property.
PollFrequency
The PollFrequency property specifies the amount of time (in milliseconds) between
the end of one polling action and the start of the next polling action. This is not
the interval between polling actions. Rather, the logic is as follows:
v Poll to obtain the number of objects specified by the value of the PollQuantity
v Process these objects. For some connectors, this may be partly done on separate
v Delay for the interval specified by the PollFrequency property.
v Repeat the cycle.
The following values are valid for this property:
v The number of milliseconds between polling actions (a positive integer).
v The word no, which causes the connector not to poll. Enter the word in
v The word key, which causes the connector to poll only when you type the letter
The default is 10000.
Important: Some connectors have restrictions on the use of this property. Where
PollQuantity
The PollQuantity property designates the number of items from the application
that the connector polls for. If the adapter has a connector-specific property for
setting the poll quantity, the value set in the connector-specific property overrides
the standard property value.
This property is valid only if the value of the DeliveryTransport property is JMS,
and the ContainerManagedEvents property has a value.
An e-mail message is also considered an event. The connector actions are as
follows when it is polled for e-mail.
v When it is polled once, the connector detects the body of the message, which it
102
Adapter for Siebel eBusiness Applications User Guide
property.
threads, which execute asynchronously to the next polling action.
lowercase.
p in the connector Command Prompt window. Enter the word in lowercase.
they exist, these restrictions are documented in the chapter on
installing and configuring the adapter.
reads as an attachment. Since no data handler was specified for this mime type,
it will then ignore the message.

Advertisement

Table of Contents
loading

Table of Contents