DAGE-MTI CCD-100 User Manual page 10

Camera system
Table of Contents

Advertisement

PIN #
1
Man Gain Pot (+5V=Max; GND=Min)
2
Man Black Pot (+5V=Dark; GND=Light)
3
Gain Switch
4
AUTO EE
5
Gamma Switch (+5V=ON; GND=OFF)
6
Power IN
7
Black Switch
8
Enhance Pot
Shield GND
GATE
connector, such as Dage P/N 737129-01 can be used. This
connector also allows the Dage InvestiGater to be used with
the CCD-100L to provide a complete system for long-term
gating. The camera mates to the InvestiGater through a
standard S-video cable such as Dage P/N 737980-01. The
pin-out and interface is as follows:
PIN # FUNCTION
1
GND
2
Power In (+12V @ 200mA)
3
Video Out
4
External Gate In (+5V=Readout; GND=GATE)
GATING
The CCD-100L can be externally gated in order to
provide additional sensitivity by inhibiting the readout of the
FUNCTION
(+5V=AUTO; GND=MAN)
(+5V=ON; GND=OFF)
(+12V @ 200mA)
(+5V=AUTO; GND=MAN)
(+5V=MAX; GND=MIN)
The gating pulse that the camera uses to
inhibit the readout of the CCD is brought in
through this connector. Gating cable 207663-
01 provides the interface. If a different
interface is required, a 4-pin male mini-DIN
REMOTE SET POS
Center
Center
AUTO
ON
AUTO
Center

Hide quick links: