OPERATION MODES:

Pressing the
key various operation modes may be selected: FROST PROTECTION, AUTOMATIC STORAGE
HEATER , EMITTER, ECOMBI MANUAL or ECOMBI AUTOMATIC.

1 - FROST PROTECTION MODE:

To select this mode press the
will be 7º C. the appliance will maintain this temperature through convector operation. Storage heater will be off in any case.
2 – AUTOMATIC STORAGE HEATER MODE:
To select this mode press the
"АС" stands for STORAGE HEATER in Spanish language. "4.0" would be the charge control position set to position 4.
As in a standard storage heater equipped with a 5- position charge control, charging settings in ECOMBI go from 0
(minimum charge) to 5 (maximum charge):
5.0 = charge 100% (during all the reduced rate time)
4.5 = 90%
4.0 = 80%
3,5 = 70%
3.0 = 60%
2.5 = 50%
2.0 = 40%
1.5 = 30%
1.0 = 20%
0.5 = 10%
0.0 = 0%
While ECOMBI is charging (electric consumption) a small red dot will appear between the A and the C in the display.
DEFERRED CHARGING:
This function in ECOMBI allows optimizing the energy management and consumption. In a off-peak period of 8 hours, if there is
the case where it is only necessary to charge at 50%, this is 4 hours. This function will make that the effective charging period
would be the last 4 hours during the off-peak period. This will make that ECOMBI is at full charge at the beginning of the
"cession" period.
In order to enable / disable this option please go to "General Settings" part in this manual and change P6 setting as ON / OFF.
PROTECTION FOR EXCESS OF TEMPERATURE IN THE ROOM:
In order to reach maximum saving and avoid unnecessary energy consumption, if there is the case that during the charging
period the temperature in the room excess the temperature set up in ECOMBI for that room, then the charging will be
interrupted until the temperature in the room decreases 1ºC.
key several times until the message
key several times until the message
8
is displayed. The set up temperature
is displayed.
.