Deciding on Where to Install the Air Conditioner
When deciding on the location of the air conditioner with the owner, the following restrictions
must be taken into account.
General
Do NOT install the air conditioner in a location where it will come into contact with the following elements:
Combustible gases
Saline air
Machine oil
Sulphide gas
Special environmental conditions
If you must install the unit in such conditions, first consult your dealer.
Indoor Unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a surface that can support its weight.
Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the
recommended length of 5 metres(16ft 5in) to be respected (10 metres/33ft maximum).
Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.
Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.
Make sure that the water dripping from the drain hose runs away correctly and safely.
Outdoor Unit
The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the
cooling circuit and seriously damage the unit.
Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.
Do not block any passageways or thoroughfares.
Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any
neighbours.
Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended
length of 5 metres (16ft 5in) to be respected (10 metres/33ft maximum).
Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
noise and vibration.
Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of
the unit.
Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.
If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height("B":
indicated in the diagram on the page opposite.) is 3 metres/9ft 10in.
Make sure that the water dripping from the drain hose runs away correctly and safely.
C C
A A
U U
T T
C C
A A
U U
T T
You have just purchased a split-type room air conditioner and it has
been installed by your installation specialist.
26
E-
Page 4
NOTE: For cooling mode, low ambient kit (ICM326H) must be
used when the outside ambient temperature is 70 deg F or less.