Reparing The; Installation; I Deciding On Where To Install The Air Conditioner - Samsung AQV09F series Installation Manual

Split-type
Hide thumbs Also See for AQV09F series:
Table of Contents

Advertisement

P
I

REPARING THE

NSTALLATION
Deciding on Where to Install the Air Conditioner
When deciding on the location of the air conditioner with the owner, the following restrictions
must be taken into account.
General
Do NOT install the air conditioner in a location where it will come into contact with the following elements:
N Combustible gases
N Saline air
N Machine oil
N Sulphide gas
N Special environmental conditions
If you must install the unit in such conditions, first consult your dealer.
Indoor Unit
N There must be no obstacles near the air inlet and outlet.
N Install the indoor unit on a surface that can support its weight.
N Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the
recommended length of 5 metres to be respected (15 metres maximum).
N Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.
N Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.
N Make sure that the water dripping from the drain hose runs away correctly and safely.
N Install the indoor unit on the wall which is far from the floor by more than 2.5 meters.
Outdoor Unit
N The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the
cooling circuit and seriously damage the unit.
N Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.
N Do not block any passageways or thoroughfares.
N Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any
neighbours.
N Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended
length of 5 metres to be respected (15 metres maximum).
N Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
noise and vibration.
N Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of
the unit.
N Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.
N If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is 7
metres.
N Make sure that the water dripping from the drain hose runs away correctly and safely.
C C
A A
U U
T T
I I
O O
C C
A A
U U
T T
I I
O O
N You have just purchased a split-type room air conditioner and it has been installed by
your installation specialist.
N This device must be installed according to the national electrical rules.
N Max input power & current is measured according to IEC standard and input power &
current is measured according to ISO standard.
4
E-
N N
N N

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aqv12f series

Table of Contents