5. To start milking, press the
releases the cluster.
If a code is assigned to the cow:
a. Make the necessary preparations as required by the code.
b. Press
Stimulation
The default setting is without stimulation pulsation:
• To activate pulsation, press
• If a code is assigned to the cow, and if you want to activate stimulation:
6. Attach the cluster.
WARNINGS:
7. Repeat steps 5 and 6 for each cow.
While milking is in process, the milk yield appears in the display. In addition,
the milker can view the conductivity and additional cow information, as
described in the following section.
8.
Cluster removal occurs when the milk flow rate drops below a predefined
level. The ACR function shuts off the vacuum and retracts the cluster.
9.
When all of the cows in the row are finished milking, release the
cows and repeat the process starting from step 4. The display is reset
when
6
+
(twice rapidly) to start milking with stimulation.
a. Make the necessary preparations as required by the code.
b. Press
to start milking with stimulation.
(Very slow cows are milked with ACR deactivated. To
deactivate the ACR press the ACR Cancel key (
The red LED glows, indicating that ACR is deactivated. When
the cow has finished milking, press the
the vacuum and retract the cluster.)
1. Automatic cluster removal does not take place in this mode.
Therefore, preventing over-milking—that is, manually
stopping the milking—is the full responsibility of the milker.
2. The Afi-lite milk meter does not automatically reset to ACR
mode. To restore ACR for the next cow, press the Cancel
ACR key. The red LED in the key turns off, indicating that
ACR is activated.
is pressed.
Afi-lite User Manual
key. This starts the vacuum and
(twice rapidly) to start milking.
+
+
+
this page updated: July 27, 2003
(three times rapidly)
).
key to shut off