IMPROPER GASKET MAINTENANCE, INCLUDING FAILURE TO REPLACE
GASKETS, CAN CAUSE AIR LEAKS RESULTING IN SMOKE-BACKS.
 
Gaskets 
1. Door 
o This unit comes with a 
should be replaced at least once every year. To replace the door gasket (Part # AC‐
DGKNC), the old gasket must first be removed entirely — prior to adding the new 
adhesive, you may have to scrape the old cement from the channel. Once the cement 
and gasket have been added, the door should be closed and latched for twenty‐four 
hours to allow the cement to harden. 
2. Window 
o If you are replacing the window gasket (Part # AC‐GGK), the new gasket will already 
have adhesive on one side. Remove the paper on the adhesive side and place the gasket 
around the outside edge of the glass, centered over the edge.  Fold the gasket edges 
over on the glass, forming a "U" shape.  
3. Combustion Blower 
o The Combustion Blower Gasket (Part # PU‐CBG) should be inspected whenever you 
remove or clean the Combustion Blower, and replaced if necessary. 
4. Combustion Blower Motor 
o The combustion blower motor gasket (Part # PU‐CMG) generally does not need 
replacement, as it is not normally removed from the unit.  However, if the exhaust 
blower is cleaned by removing the motor, rather than the entire blower assembly, this 
gasket must be inspected and replaced as necessary. 
5. Cradle 
o The cradle gasket (Part # PU‐CGEP) needs to be replaced every time the cradle is 
removed, which will only be necessary during the yearly maintenance. 
6. Hopper/Hopper Lid 
o There is one gasket under the top, and one under the lid.  Both of these can be replaced 
using the same gasket kit (Part # PU‐HLG).  Both should be inspected and replaced 
yearly. 
7. Ash Pan 
o The ash pan gasket should be inspected and replaced annually, as well. 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
REPLACING COMPONENTS 
5
/
" rope gasket in the channel around the door opening that 
8
37
QUESTIONS.