INSTALLATION 
Mobile Home Installation 
 The England's Stove Works, Inc. outside air kit MUST be used for installation of this unit in a mobile 
home.  Please see the "Outside Air" section on page 15 for more information regarding outside air 
connections. 
 The outside air inlet must be kept clear of leaves, ice and other debris. Keeping the outside air inlet 
free of restriction is crucial to preventing air starvation and smoke spillage. 
 The pellet stove MUST be secured to the floor of the mobile home using lag bolts and the holes 
provided in the bottom of the base for this purpose.  Outdoor‐aired space heaters must be 
attached to the structure. 
 The pellet stove MUST be grounded with #8 solid copper grounding wire (or equivalent), 
terminated at each end with an NEC approved grounded device. 
 Carefully follow all clearances listed in the appropriate section of this manual AND follow the 
venting manufacturer's minimum clearance requirements.  Similarly, be certain the venting system 
used is approved for mobile home use. 
 Installation must be in accordance with Manufacturers Home & Safety Standard (HUD) CFR 3280, 
Part 24 as well as any applicable local codes. 
Use silicone to create an effective vapor barrier at the location where the chimney or outside air 
ducting passes through to the exterior of the structure.
 
 
Chimney Cap/Spark Arrestor 
 
 
Joist Shield/Firestop 
 
 
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL AND CEILING/ROOF MUST 
BE MAINTAINED.  DO NOT CUT THROUGH FLOOR JOISTS, WALL STUDS, CEILING TRUSSES OR ANY 
OTHER SUPPORTING MATERIAL WHICH COULD BE DETRIMENTAL TO THE STRUCTURAL INTEGRITY OF 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
CAUTION 
THE HOME.  
WARNING: DO NOT INSTALL IN A SLEEPING ROOM. 
QUESTIONS.
For high altitude installations 
(above 4,000 ft.), the vent pipe 
should be increased from 3‐inch 
 
13
(3") to four‐inch (4").
Roof Flashing and Storm 
Collar 
Mobile Home Approved 
Type L or Type PL Pellet 
Vent Pipe 