Standards Index - Generac Power Systems XP4000 Professional Owner's Manual

Xp professional series portable generator
Hide thumbs Also See for XP4000 Professional:
Table of Contents

Advertisement

Available languages

Available languages

Keep hands, feet, clothing, etc., away from drive belts, fans, and
other moving or hot parts. Never remove any fan guard while
the unit is operating.
Adequate, unobstructed flow of cooling and ventilating air
is critical to correct generator operation. Do not alter the
installation or permit even partial blockage of ventilation
provisions, as this can seriously affect safe operation of the
generator. The generator MUST be operated outdoors.
When working on this equipment, remain alert at all times. Never
work on the equipment when physically or mentally fatigued.
Inspect the generator regularly, and contact the nearest
Authorized Dealer for parts needing repair or replacement.
Before performing any maintenance on the generator, disconnect
its battery cables to prevent accidental start up. Disconnect the
cable from the battery post indicated by a NEGATIVE, NEG or
(–) first. Reconnect that cable last.
Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts, and may result in
dangerous operating conditions from leaking exhaust gases,
fuel leakage, oil leakage, etc.
Do NOT operate generator in the rain.
ELECTRICAL HAZARDS
All generators covered by this manual produce dangerous
electrical voltages and can cause fatal electrical shock. Utility
power delivers extremely high and dangerous voltages as does
the generator when it is in operation. Avoid contact with bare
wires, terminals, connections, etc., while the unit is running.
Ensure all appropriate covers, guards and barriers are in place
before operating the generator. If work must be done around
an operating unit, stand on an insulated, dry surface to reduce
shock hazard.
Do not handle any kind of electrical device while standing
in water, while barefoot, or while hands or feet are wet.
DANGEROUS ELECTRICAL SHOCK MAY RESULT.
The National Electrical Code (NEC) requires the frame and
external electrically conductive parts of the generator to be
connected to an approved earth ground. Local electrical codes
also may require proper grounding of the generator electrical
system.
In case of accident caused by electric shock, immediately shut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID
DIRECT CONTACT WITH THE VICTIM. Use a non-conducting
implement, such as a rope or board, to free the victim from the
live conductor. If the victim is unconscious, apply first aid and
get immediate medical help.
Never wear jewelry when working on this equipment. Jewelry
can conduct electricity resulting in electric shock, or may get
caught in moving components causing injury.
IMPORTANT SAFETY INSTRUCTIONS
For fire safety, the generator must be operated and maintained
properly. Operation must always comply with applicable codes,
standards, laws and regulations. Adhere strictly to local,
state and national electrical and building codes. Comply with
regulations the Occupational Safety and Health Administration
(OSHA) has established. Also, ensure that the generator is
operated in accordance with the manufacturer's instructions
and recommendations. Do not alter the construction of the
generator or change controls which might create an unsafe
operating condition.
Keep a fire extinguisher near the generator at all times.
Extinguishers rated "ABC" by the National Fire Protection
Association are appropriate for use on the standby electric
system. Keep the extinguisher properly charged and be familiar
with its use. If there are any questions pertaining to fire
extinguishers, consult the local fire department.
Gasoline is extremely FLAMMABLE. Never add fuel while unit is
running or hot. Avoid spilling gasoline on a hot engine. Allow
engine/unit to cool entirely before adding fuel. Do not over fill
fuel tank. Allow room for fuel expansion. Wipe up fuel spills
immediately. If tank is overfilled, fuel can overflow onto a hot
engine and cause FIRE. Never fill fuel tank indoors.
Do not smoke around the generator. Wipe up any fuel or oil spills
immediately. Ensure that no combustible materials are left on or
near the generator, as FIRE or EXPLOSION may result. Keep the
area surrounding the generator clean and free from debris.
Gasoline is extremely FLAMABLE and EXPLOSIVE.

STANDARDS INDEX

In the absence of pertinent standards, codes, regulations and laws,
the published information listed below may be used as a guideline
for operation of this equipment. Always reference the latest revision
available for the standards listed.
1. NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC
2. Article X, NATIONAL BUILDING CODE, available from the
3. AGRICULTURAL WIRING HANDBOOK, available from the Food
4. ASAE EP-3634, INSTALLATION AND MAINTENANCE OF
5. NFPA No. 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS
Portable Generator System
FIRE HAZARDS
EXPLOSION HAZARDS
CODE.
American Insurance Association, 85 John Street, New York,
N.Y. 10038.
and Energy Council, 909 University Avenue, Columbia, MO
65201.
FARM STANDBY ELECTRICAL SYSTEMS, available from the
American Society of Agricultural Engineers, 2950 Niles Road,
St. Joseph, MI 49085.
CODE.
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents