INSTALLER MUST LEAVE INSTRUCTIONS WITH THE OWNER AFTER INSTALLATION
IMPORTANT: Owner please fill out and mail warranty card supplied with heater.
THIS IS A HEATING APPLIANCE. ANY SAFETY
SCREEN OR GUARD REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED PRIOR TO
OPERATING THE APPLIANCE.
Due to high temperatures, the appliance should
be located out of traffic and away from furniture
and draperies.
Children and adults should be alerted to the
hazard of high surface temperature and should
be kept away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room with the appliance.
Do not place clothing or other flammable material
on or near the appliance.
Installation and repair should be done by a qualified
service person.
The appliance should be inspected before use
and at least annually by a qualified service person.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments,
burners, and circulating air passageways of the
appliance be kept clean.
GENERAL INFORMATION
This series is design certified by the CSA Laboratories
as an Unvented Heater, and must be installed according
to these instructions.
This appliance is intended for supplemental heating.
W A R N I N G
Composici n
C
M
INSTALLATION
AND
OWNER'S GUIDE
Effective Date: June 2006
ANY ALTERATION TO THE ORIGINAL DESIGN,
INSTALLED OTHER THAN AS SHOWN IN THESE
INSTRUCTIONS, OR USED WITH A TYPE OF GAS
NOT SHOWN ON THE RATING PLATE IS PROHIBITED
AND VOIDS THE WARRANTY.
The installation must conform to local codes. In the
absence of local codes, the installation must conform to
the National Fuel Gas Code, also known as NFPA 54
and ANSI Z223.1-latest edition.
Installation and service must be performed by a qualified
installer (i.e., a . licensed heating contractor or gas
company personnel).
WARNING: If the information in
this manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any telephone in your
building.
• Immediately call your gas
supplier from a neighbor's
telephone.
supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Any change to this heater or its control can be dangerous.
For proper ventilation, provide a minimum fresh air opening of
one square inch for every 1,000 BTU s of gas burner capacity.
Y
CM
MY
CY CMY
K
VENT-FREE
ROOM HEATER
CK18M-4-NG/LP
Models:
CK30M-4-NG/LP
Follow the gas
PN 43126170

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CK18M-4-NG/LP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SunStar CK18M-4-NG/LP

  • Page 1 T (Convertido)-1 13/3/08 10:27 P gina 1 CY CMY INSTALLATION VENT-FREE OWNER'S GUIDE ROOM HEATER CK18M-4-NG/LP Models: Effective Date: June 2006 CK30M-4-NG/LP INSTALLER MUST LEAVE INSTRUCTIONS WITH THE OWNER AFTER INSTALLATION IMPORTANT: Owner please fill out and mail warranty card supplied with heater.
  • Page 2 T (Convertido)-1 13/3/08 10:27 P gina 2 CY CMY W A R N I N G S Read this Installation and Owners Guide carefully and completely before attempting to install, operate or service this heater. Improper use of this heater can result in serious bodily injury or death due to hazards of fire, explosion, electrical shock or carbon monoxide poisoning.
  • Page 3 T (Convertido)-1 13/3/08 10:27 P gina 3 CY CMY 20. The National Fuel Gas Code defines a confined WARNING: If the area in which the space as a space whose volume is less than 50 heater may be operated is smaller than that per 1,000 Btu/hr (4.8 m...
  • Page 4 T (Convertido)-1 13/3/08 10:27 P gina 4 CY CMY Propane (LP-Gas) is a flammable gas that can cause the members of your household. Someday when fires and explosions. In its natural state, propane is there may not be a minute to lose, everyone's safety odorless and colorless.
  • Page 5 T (Convertido)-1 13/3/08 10:27 P gina 5 CY CMY CK18M-4-NG CK 18M-4-LP CK30M-4-NG CK30M-4-LP MODEL MODEL MODEL MODEL BTU/hr Input: 18,000 16,500 30,000 27,000 Type Gas: Natural Gas LP Gas Natural Gas LP Gas Ignition Type: Piezo ignitor...
  • Page 6: Wall Mount Installation

    T (Convertido)-1 13/3/08 10:27 P gina 6 CY CMY WALL MOUNT INSTALLATION IMPORTANT: Before installing this heater, make sure that a wall stud is located in the center of the unit. This wall stud will give better support to the unit. See the following instructions in figure 2.2 to place the “C”...
  • Page 7 T (Convertido)-1 13/3/08 10:27 P gina 7 CY CMY INSTALLATION TO GAS SUPPLY 6. The supply system must include a manual shut-off valve, a union in the line, and a plugged 1/8" NPT 1. The gas supply must comply with local codes, or in tap.
  • Page 8: Heater Service

    T (Convertido)-1 13/3/08 10:27 P gina 8 CY CMY HEATER SERVICE If that fails to solve the problem, remove the wire clip that holds the metal strip onto the pilot assembly. Remove To service the heater, turn off the gas supply and the cover and blow any dust out.
  • Page 9: What To Do If You Smell Gas

    T (Convertido)-1 13/3/08 10:27 P gina 9 CY CMY If you do not follow these instructions exactly, a fire or explosion may result causing property damage, WARNING personal injury or loss of life. This appliance has a pilot that must be normally •...
  • Page 10 T (Convertido)-1 13/3/08 10:27 P gina 10 CY CMY Composici n...
  • Page 11 T (Convertido)-1 13/3/08 10:27 P gina 11 CY CMY TROUBLE CAUSE SOLUTION PILOT TROUBLE • Not pushing piezo all the way down • Review Lighting Instructions until "click" • Lead wire loose at piezo igniter • Tighten connection •...
  • Page 12 T (Convertido)-1 13/3/08 10:27 P gina 12 CY CMY MODELS: CK18M-4-LP (Propane Gas) CK18M-4-NG (Natural Gas) Composici n...
  • Page 13 T (Convertido)-1 13/3/08 10:27 P gina 13 CY CMY Composici n...
  • Page 14 T (Convertido)-1 13/3/08 10:27 P gina 14 CY CMY MODELS: CK18M-4-LP and CK30M-4-LP (Propane Gas) CK18M-4-NG and CK30M-4-NG (Natural Gas) Composici n...
  • Page 15: How To Order Repair Parts

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Order parts from your local dealer or through SunStar Heating Products, Inc. Shipments of parts are contingent upon strikes, fires and all other causes beyond our control.
  • Page 16 T (Convertido)-1 13/3/08 10:27 P gina 16 CY CMY PN 43126170 22.130.177 Rev.:d Composici n...

This manual is also suitable for:

Ck30m-4-ng/lpCk18m-4-ngCk30m-4-ngCk18m-4-lpCk30m-4-lp

Table of Contents