SunStar SGM3 Installation And Operation Instructions Manual
SunStar SGM3 Installation And Operation Instructions Manual

SunStar SGM3 Installation And Operation Instructions Manual

Starglo millivolt series infrared radiant ceramic heater

Advertisement

INSTALLATION AND OPERATION INSTRUCTIONS

OWNER / INSTALLER:
read and understood before installing, operating or servicing this heater.
INFRARED RADIANT CERAMIC HEATER
Models:
! INSTALLER:
This manual is the property of the owner. Please present this manual
to the owner when you leave the job site.
Improper installation, adjustment, alteration, service, or maintenance can cause
property damage, injury or death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
In locations used for the storage of combustible materials, signs must be posted to
specify the maximum permissible stacking height to maintain the required clearances
from the heater to the combustibles. Signs must either be posted adjacent to the
heater thermostats or in the absence of such thermostats, in a conspicuous location.
NOT FOR RESIDENTIAL USE.
This heater is not approved in any residential application. This includes (but is not
limited to) the home, living quarters, attached garages, etc. Installation in residential
indoor spaces may result in property damage, asphyxiation, and serious injury or
death.
!IMPORTANT: SAVE THIS MANUAL FOR FUTURE REFERENCE.
Post Office Box 36271
Phone (704) 372-3486 – www.sunstarheaters.com – email:
For your safety this manual must be carefully and thoroughly
STARGLO MILLIVOLT SERIES
SGM3, SGM6, SGM10
UNVENTED (For Indoor Installation Only)
SUNSTAR HEATING PRODUCTS, INC.
 306 West Tremont Avenue
(28236)
 Charlotte, North Carolina
(28203
)
info@sunstarheaters.com
Form #43219030
Sept 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SGM3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SunStar SGM3

  • Page 1: Installation And Operation Instructions

    For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. STARGLO MILLIVOLT SERIES INFRARED RADIANT CERAMIC HEATER SGM3, SGM6, SGM10 Models: UNVENTED (For Indoor Installation Only) ! INSTALLER: This manual is the property of the owner. Please present this manual to the owner when you leave the job site.
  • Page 2: Table Of Contents

    WHAT TO DO IF YOU SMELL GAS: DO NOT try to light any appliance. Extinguish any open flame. Open windows. DO NOT touch any electrical switch. DO NOT use any telephone in your building. Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier's instructions.
  • Page 3: Safety

    SAFETY This heater is a self-contained infrared radiant ceramic heater. Safety information required during installation and operation of this heater is provided in this manual and the labels on the product. The installation, service and maintenance of this heater must be performed by a contractor qualified in the installation and service of gas fired heating equipment.
  • Page 4 SAFETY REQUIREMENTS  The heater area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.  This heater is designed for use with one type of gas (LPG or Natural). Make sure that the type of gas to be supplied to this heater matches that shown on the heater rating plate.
  • Page 5: Minimum Clearances To Combustibles

    Although these heaters may be used in many applications other than space heating (e.g., process heating), SunStar Heating Products, Inc. will not recognize the warranty for any use other than space heating. This heater is for Indoor Installation only and can be used in Unvented mode. The term Unvented actually means Indirect Vented.
  • Page 6 SIDES CEILING BELOW BACK SIDES CEILING BELOW w/Reflector w/Reflector w/Reflector w/Reflector MODEL BACK Extension SIDES Extension CEILING Extension BELOW Extension SGM3 24” 36” 24” 36” 24” 36” 48” 126” SGM6 36” 36” 30” 36” 36” 36” 72” 126” SGM10 45”...
  • Page 7: Sgm Specifications

    For further information consult NFPA 13. Always observe applicable state and local codes.  SGM SPECIFICATIONS INPUT MINIMUM ORIFICE SHIPPING MODEL TYPE BTU/HR MOUNTING HEIGHT* SIZE WEIGHT SGM3-N1 Natural 26,000 12 ft. #42 (0.0935) 30 lbs. SGM3-L1 Propane 26,000 12 ft. #53 (0.0595 30 lbs. SGM6-N1A...
  • Page 8: Sgm Dimensions

    SGM DIMENSIONS HANGING The heater can be mounted with the reflector horizontal or angled up to 45º off the horizontal. When the heater is to be angle mounted, make sure the controls are on the lower side of the heater. Coil chains (No. 2 or larger) or rigid supports may be used to mount the heater.
  • Page 9: Optional Parabolic Reflector Extension Assembly

    OPTIONAL PARABOLIC REFLECTOR EXTENSION ASSEMBLY The heater is completely factory assembled and requires no field assembly. If the optional parabolic reflector extension is utilized, locate and identify the end panels and side panels as shown in the following diagram. Attach the side panels as shown. Attach the end panels so that the end flanges of the end panels overlap the side panels.
  • Page 10 1. Connect to the supply tank or manifold in accordance with the latest edition of National Fuel Gas Code (ANSI Z223.1), and local building codes. Authorities having jurisdiction should be consulted before the installation is made. 2. All gas supply lines must be located in accordance with the required clearances to combustibles below the heater as listed on the nameplate of the heater.
  • Page 11: Instructions For Pressure Test Gauge Connection

    Supply Pressure Model Gas Type Manifold Pressure  Minimum Maximum Natural Gas 3.5” W.C. 4.5” W.C. 14.0” W.C. SGM3 Propane Gas 10.0” W.C. 11.0” W.C. 14.0” W.C. Natural Gas 6.0” W.C. 7.0” W.C. 14.0” W.C. SGM6 and SGM10 Propane Gas 10.0”...
  • Page 12: Thermostat Wiring Installations

    This heater requires ventilation in the building to dilute the product of combustion and provide fresh air for efficient combustion. Power ventilation is recommended, and the minimum vent flow required is as follows: SGM3 = 109 cfm SGM6 = 218 cfm...
  • Page 13: Lighting And Shutdown Instructions

    LIGHTING AND SHUTDOWN INSTRUCTIONS STANDING PILOT IGNITION SYSTEM (Ignition Suffix “1”) Turn the dial to “PILOT.” Press the dial in and light the pilot. Hold for 60 seconds and release. Turn the dial counterclockwise to “ON.” Use this position for thermostat control Set the thermostat ...
  • Page 14: Replacing Parts

    Remove the reflector mounting panels from the heater body e) Remove the emitter face from the heater body. This surface unit is attached by ¼” Hex Head machine screws (10 on the SGM3, 16 on the SGM6, and 26 on the SGM10) Use caution in this operation as the emitter surface is fragile.
  • Page 15: Replacement Parts Guide

    REPLACEMENT PARTS GUIDE MODELS: SGM3-(N1, L1 Item No. Part No. Description 42129000 Plenum Box Assembly 42192000 Emitter Kit (includes items 3 & 4) 40446080 End Gasket (Qty. 2) 40446130 Side Gasket (Qty. 2) 42133000 Screen Retainer (Qty. 2) 40670050 Reverb Screen (Pilot)
  • Page 16: Form #43219030 Sept

       IMPORTANT:  Please order by Part Number, not by Item Number.  Refer to complete Model Number when ordering.  All replacement parts available when ordering. MODEL NUMBER SUFFIXES: N = Natural Gas L = Propane Gas 1 = Self-Generating Standing Pilot ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY.
  • Page 17 MODELS: SGM6-(N1A, L1) Item No. Part No. Description 40714000 Plenum Box Assembly 41218000 Emitter Kit (includes items 3 & 4) 40446080 End Gasket (Qty. 2) 40446090 Side Gasket (Qty. 2) 40608000 Screen Retainer (Qty. 2) 40670030 Reverb Screen (pilot) 40710020 End Reverb Baffle 40621000 End Flue Collar...
  • Page 18 Form #43219030 Sept 2012...
  • Page 19 MODELS: SGM10-(N1A, L1) Item No. Part No. Description 40742000 Plenum Box Assembly 41219000 Emitter Kit (includes items 3 & 4) 40446080 End Gasket (Qty. 2) 40446110 Side Gasket (Qty. 2) 40747000 Screen Retainer (Qty. 2) 40670040 Reverb Screen (pilot) 40710010 Reverb Baffle Assembly (ignition end) 40710020 Reverb Baffle (back end)
  • Page 20 Form #43219030 Sept 2012...
  • Page 21: Warning Card

    WARNINGS CARD This card is furnished with each heater. Additional copies may be ordered under part no. 43344980. Form #43219030 Sept 2012...
  • Page 22 LIMITED WARRANTY: SunStar Heating Products, Inc., the manufacturer, warrants to the original owner of any SunStar infrared gas heater that said heater will be free from defects in material or workmanship under normal use and service. The heater(s) shall be installed, used and maintained strictly in accordance with the manufacturer's instructions.

This manual is also suitable for:

Sgm6Sgm10

Table of Contents