Technical Specifications; General Product Care; Troubleshooting Guide - GE 21825 User Manual

Digital cordless telephone with dual mode caller id
Table of Contents

Advertisement

Deregister HS
If several handsets are registered on one base station, they can
deregister each other mutually. The last handset can not be
deregistered.
Press
key until the BASE menu appears and press "Int/ok"
key.
Press
or
key to select the required submenu and
press "Int/ok" key.
Enter the PIN (factory setting = 0000) and press "Int/ok" key.
If necessary, Use
press "Int/ok" key.
Press "Int/ok" key to confirm.

Technical Specifications

Handset
Operating
Approx. 8.5 hours talk time
Time:
(average
Approx. 100 hours standby
values*)
AC / DC Adaptor
VD060035D
Input: 230V AC / 50 Hz
Output: 6V DC, 350mA
Single-phase AC excluding IT installations
defined by the EN 60950 standard.
Caution: the network voltage is classified
as a hazard by the criteria of this standard.
AC / AC Adaptor (for
VA070020D
Handset charging)
Input: 230V AC / 50 Hz
Output: 7V AC, 200mA
Single-phase AC excluding IT installations
defined by the EN 60950 standard.
Caution: the network voltage is classified
as a hazard by the criteria of this standard.
Telephone connection
Appliance designed for connection to an
analogue telephone line class TRT3
(telecommunications network voltage) as
defined by the EN 60950 standard.
Rechargeable Battery
GP60AAAHC, 1.2V / 600mAh / Ni-MH,
AAA x 2 or equivalent
"WEEE" weight
447g
* For guidance only, depends on initial battery charge.

General Product Care

Simply wipe the base station with a damp cloth or an antistatic wipe.
Never use a dry cloth as this can cause static discharge.
Periodically clean the charge contacts on the handset, base and
charger with a soft cloth.

Troubleshooting Guide

When you forget base PIN, following the procedure to Reset the units.
ALL MEMORY AND SETTING WILL BE LOST.
Refer to handset – Call Log Operation procedure, select
DELETE ALL to delete all Call Log Memories in handset.
Disconnect the line cord and AC power supply.
Hold "PAGE" button and plug in the AC power supply (in-use
LED will be on).
Release "PAGE" button after hear two beep tones and press it
two times again.
The In-Use LED will turn Off.
The unit will return to its default setting a PIN code (0000).
Unplug AC power of base station and plug in again, handset
LCD will display " ---- ".
Following "Registering Additional Handsets" to register all
handsets again.
or
key to select the handset and
14

Advertisement

Table of Contents
loading