Clifford Concept 450 Installation Manual page 8

Car security
Hide thumbs Also See for Concept 450:
Table of Contents

Advertisement

h1/12 white/red light flash input
This wire is the input for the on-board dual light flash relay. If the vehicle has positive
parking light activation wires, connect this wire to a constant (+) 12V source that is
fused at 15A or higher (be sure to use the supplied fuse holder and a 15 amp fuse).
If the vehicle parking light activation wire is negative, connect this wire to a chassis
ground location.
h1/13 and h1/14 white parking light output
These wires are the output of an on-board dual make relay and should be connected
to wires in the vehicle that control the parking light wire polarity. The dual outputs are
designed for European vehicles with isolated parking light systems. If the vehicle's
parking lights are controlled by a single wire, connect both WHITE wires to it.
I I M M P P O O R R T T A A N N T T ! ! The polarity of this wire is determined by the connection of the H1/12
light flash input wire. Always confirm light flash polarity before connecting H1/12 or
damage to the vehicle lighting system could occur.
h1/15 black/white dome light supervision output
Connect the H1/15 BLACK/WHITE wire to the vehicle domelight circuit trigger wire.
h1/16 red/white accessory a output
When the system receives the code controlling the accessory output, this wire will sup-
ply an output as long as the transmission continues. This is often used to operate a
trunk/hatch release or other relay-driven function. All accessory outputs can be pro-
grammed to different types of outputs. Please see Programming Note #6.
I I M M P P O O R R T T A A N N T T ! ! Never use this wire to drive anything but a relay or a low-current input!
The transistorized output can only supply 200 mA of current. Connecting directly to a
solenoid, motor, or other high-current device will cause it to fail.
h1/17 orange ground when armed
This wire provides a (-) ground output as long as the system is armed and will cease
when the system is disarmed. This output can be used for an additional immobilizer
relay or to control additional accessories such as window automation, voice modules,
or pagers.