Payne PA10 Series Product Data page 11

10 seer 3-phase air conditioner
Hide thumbs Also See for PA10 Series:
Table of Contents

Advertisement

EVAPORATOR
AIR
75
Capacity
MBtuh†
CFM
EWB
Total
Sens‡
PA10060-A Outdoor Section With CC5A/CD5AA060 Indoor Section
72
65.78
33.91
67
60.83
41.73
1950
62
55.48
49.20
57
52.32
52.32
72
66.67
35.03
67
61.97
43.97
2000
62
56.63
52.35
57
54.52
54.52
72
67.33
36.04
67
62.76
46.05
2250
62
57.55
55.11
57
56.36
56.36
Indoor
Section
Size
CAR**
6021A**
6024A**
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor
unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Unit kW is total of indoor and outdoor unit kilowatts.
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Total
Total
MBtuh†
System
System
kW**
Total
Sens‡
kW**
5.12
63.76
33.16
5.59
5.02
58.56
40.81
5.49
4.93
53.14
48.04
5.36
4.84
50.52
50.52
5.26
5.24
64.66
34.41
5.71
5.14
59.61
43.12
5.60
5.04
54.24
51.12
5.51
5.01
52.66
52.66
5.44
5.35
65.30
35.52
5.82
5.25
60.41
45.31
5.71
5.14
55.14
53.81
5.61
5.13
54.42
54.42
5.60
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.98
0.96
0.98
0.96
0.98
0.99
1.00
1.00
1.00
0.99
0.98
0.99
0.98
0.99
0.98
0.99
95
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Total
Sens‡
kW**
Total
61.29
32.26
6.11
58.55
56.01
39.73
6.00
53.08
50.44
46.70
5.77
47.70
48.89
48.89
5.76
46.35
62.19
33.57
6.23
59.39
57.00
42.08
6.11
54.07
51.50
49.66
5.93
48.58
50.94
50.94
5.94
48.24
62.84
34.77
6.35
60.00
57.75
44.36
6.22
54.80
52.43
52.43
6.08
49.85
52.22
52.22
6.07
49.95
Indoor
Section
Size
CK5A/CK5BX
060
CNRV*
6024A**
CNRH*
6024A**
CSRH*
6012A**
PF1MNB
060
070
PF1MNC
060
—11—
105
115
Capacity
Total
MBtuh†
System
Sens‡
kW**
Total
Sens‡
31.20
6.68
55.48
30.06
38.47
6.52
50.44
37.61
45.29
6.26
44.84
43.75
46.35
6.19
44.33
44.33
32.57
6.80
56.30
31.50
40.90
6.67
50.98
39.65
48.58
6.40
45.98
45.98
48.24
6.38
46.15
46.15
33.87
6.93
56.93
32.86
43.27
6.78
51.66
41.98
49.85
6.59
47.51
47.51
49.95
6.58
47.72
47.72
Cooling
Capacity
Power
1.00
0.98
0.98
0.96
0.98
0.96
1.00
0.98
1.01
1.04
1.02
1.01
1.01
1.02
Total
System
kW**
7.30
7.01
6.78
6.69
7.42
7.23
6.96
6.89
7.54
7.37
7.14
7.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents